Controller Functionality 
52 
AYC-Ex5 and AYC-T65 Installation and Programming Manual 
if the door does not close prior to the end of this period, the 
controller activates the auxiliary relay. The auxiliary setting defines the 
door-ajar time. 
6.9.10.9
  Auxiliary Mode 8 
Auxiliary input function: Green LED control 
Auxiliary output activated by: Valid user code, Auxiliary code 
For example, in Auxiliary Mode 8, the controller can function as a 
two-door controller and also provide indicator functionality control. 
The auxiliary relay is connected to the lock on the second door. The 
auxiliary setting defines the door open time for the second door. The 
auxiliary input is used to control the Door indicator. If the auxiliary 
input is open, the indicator flashes green; if the auxiliary input is 
closed, the door indicator flashes red. 
 
This mode takes control of the Door indicator LED. 
The indicator LED is not be lit when: 
  A valid code is entered 
  While in secure mode, when waiting for a secondary code 
6.9.10.10
 Auxiliary Mode 9 
Auxiliary input function: Red LED control 
Auxiliary output activated by: Valid user code, Auxiliary code 
For example, in Auxiliary Mode 9, the controller can function as a 
two-door controller and also provide indicator functionality control. 
The auxiliary relay is connected to the lock on the second door. The 
auxiliary setting defines the door open time for the second door. The 
auxiliary input is used to control the indicator. If the auxiliary input is 
open the door indicator flashes red; if the auxiliary input is closed the 
door indicator flashes green. 
 
This mode takes control of the Door indicator LED. 
The indicator LED is not be lit when: 
  A valid code is entered 
  While in secure mode, when waiting for a Secondary code