Tait International Limited TBCK4X 用户手册

下载
页码 138
 
TB9400 Installation and Operation Manual
Installation
87
© Tait Limited December 2013 (Draft)
5.6.2
Connecting AC Power
The PMU is designed to accept a mains input of 88 to 264VAC at 45 to 
65Hz. A standard 3-wire grounded socket outlet must be used to supply the 
AC power. The socket outlet must be installed near the equipment and must 
be easily accessible. This outlet should be connected to an AC power 
supply capable of providing at least 600W. The requirements of two typical 
AC supplies are given in the following table.
Your base station should come supplied 
with a power supply cord to connect the 
male IEC connector on the PMU to the 
local AC supply. The pins of the IEC 
connector on the PMU are identified at 
right.
Nominal Supply
Current Requirement
a
a. The actual current consumption of the base station will be lower than these re-
quirements (refer to the Specifications Manual for more information).
Circuit Breaker/Fuse 
Rating
a
115VAC
8A
10A
230VAC
4A
6A
ground
rear view
neutral
phase