Installing or Replacing Batteries
Note: You must remove all batteries to reset the low battery signal before installing new batteries. Always replace
all three batteries. Allow three minutes after installing the batteries for the sensor to become operational before
initiating a Walk Test.
Use only 3V lithium CR-123A batteries. Use the following steps to install the batteries:
Use only 3V lithium CR-123A batteries. Use the following steps to install the batteries:
1. Remove the unit from the wall mounting bracket. See Mounting the Unit.
2. Remove all batteries (if installed) before installing new batteries.
3. Observe polarity and insert the three lithium batteries into the battery holder where indicated in Figure 6.
2. Remove all batteries (if installed) before installing new batteries.
3. Observe polarity and insert the three lithium batteries into the battery holder where indicated in Figure 6.
Caution: Risk of fire, explosion, and burns. Do not recharge, disassemble, heat above 212°F (100°C), or
incinerate. Properly dispose of unused batteries.
Tamper
Opening Tab
Battery
Compartment
Switches
Switch Settings
33'
(10.1m)
50'
(15.2m)
STD
BI
Figure 6: 1125 PIR Switches
Programming the PIR in the Panel
Refer to the panel programming guide as needed. Program the device as a zone in
Zone Information during panel
programming. Typically select the Night or Exit zone type for the 1125 PIR. At the Serial Number: prompt, enter the
serial number recorded from the back of the device case. Continue to program the zone as directed in the panel
programming guide.
Note: When a receiver is installed or powered down and powered up or the panel is reset, the supervision timer
Note: When a receiver is installed or powered down and powered up or the panel is reset, the supervision timer
cycle restarts.
Note: You can re-use a device in another system after the serial number has been previously programmed. Remove
Note: You can re-use a device in another system after the serial number has been previously programmed. Remove
the device battery, press and hold the tamper switch for one second to clear the panel house code from the device
memory and set the device back to factory defaults.