Digital Monitoring Products Inc PC0191 用户手册
Digital Monitoring Products
1101 Installation Guide
2
Magnet Assembly
Only one magnet assembly is required for internal reed switch operation. Depending on the installation
Only one magnet assembly is required for internal reed switch operation. Depending on the installation
requirements, either the standard magnet assembly or the commercial magnet assembly can be used. See Figures 3
and 4. Snap the supplied magnet into the desired housing prior to mounting.
Installing the Transmitter
1. Remove the transmitter cover by pushing the button on the end of the cover and gently pulling upwards.
2. Remove the battery (if installed).
3. Hold the transmitter base in place with the reed switch near the area where you plan to mount the magnet.
4. Place one screw into the mounting hole location shown in Figure 5 and secure the housing to the surface.
5. Place the magnet housing base on the surface near one of the internal reed switch locations (see the magnet
2. Remove the battery (if installed).
3. Hold the transmitter base in place with the reed switch near the area where you plan to mount the magnet.
4. Place one screw into the mounting hole location shown in Figure 5 and secure the housing to the surface.
5. Place the magnet housing base on the surface near one of the internal reed switch locations (see the magnet
alignment markers on the transmitter base) and use the provided screws to secure the magnet base in place.
See Figures 3 and 4.
6. Place the magnet and transmitter housing covers back on their bases.
Internal and External Contact Mounting
When connecting an external contact to
When connecting an external contact to
the terminal block, using 18 or 22 gauge
unshielded wire is recommended. Do not use
twisted pair or shielded wire. Connect the
external contact as normally open (N/O) or
normally closed (N/C) without any end-of-line
resistor. Refer to the Contact option under
Zone Information in the appropriate panel
programming guide.
When using both contacts, you must use
When using both contacts, you must use
consecutive zone numbers. Refer to the
following examples:
• XR500, XR350/XR550 systems - zones
562 and 563 or zones 893 and 894
• XR100 and XR150 systems - zones 523
and 524 or zones 593 and 594
• XT30/XT50 Series - zones 31 and 32 or
zones 34 and 41
• XTLplus Series - zones 3 and 4
Note: For UL listed installations, program the external contact as Normally Closed (N/C).
Refer to the Contact option under Zone Information in the appropriate panel programming guide.
Figure 3: Standard
Magnet Assembly
Figure 4: Commercial
Magnet Assembly
Cover
Magnet
Screws
Mounting
Base
Cover
Screws
Magnet
Figure 6: External Contact Wiring
Window - External Contact
Door - Internal Contact
Magnet with
External Contact
1101
Transmitter
Figure 5: Internal and External Contact Points
Red Survey
LED
External Contact
Terminal Block
Internal Contact
Magnetic Reed Switches
Battery Location
Mounting Hole
Magnet Alignment
Marker
Magnet Alignment
Marker
Magnet with
1101