Honeywell International Inc. 8DL5800RL-2 用户手册

下载
页码 2
K3790V1  6/07  Rev. A
ADEMCO 5800RL
 
Wireless Relay Module
INSTALLATION AND SETUP GUIDE 
 
INTRODUCTION 
The ADEMCO 5800RL is a Wireless Relay Module that 
enables use of remote sounders and/or remote arm/disarm 
indicators using two relays activated by wireless signals from 
the LYNX control (see Figure 1). The 5800RL can also send 
tamper and supervision signals to the LYNX if so 
programmed. The 5800RL is compatible with LYNX controls 
having software versions 9.0 or higher.  Refer to the LYNX 
control installation and setup guide for software compatibility 
and zone programming information. 
 
5800RL
RELAY
MODULE
TAMPER AND
SUPERVISION
SIGNALS SENT
TO CONTROL
MODULE'S 2
RELAYS ARE
ACTIVATED BY
SYSTEM
CONDITIONS
AWAY
OFF
STAY
AUX
5800RF-004-V0
 
 
Figure 1.  Lynx Interface Diagram 
 
MOUNTING LOCATION GUIDELINES 
Use the following guidelines when selecting a mounting 
location for the 5800RL Relay Module (see Figure 2): 
•  Mount the 5800RL in a high location for best wireless 
reception. 
•  Do not mount the 5800RL on or near metal objects. This 
decreases range and/or blocks wireless transmissions. 
•  Locate the 5800RL at least 10 feet from any remote 
keypad to avoid interference from the microprocessors in 
those units. 
•  To avoid voltage loss that occurs on long power lines, 
mount the external power supply unit in close proximity to 
the 5800RL. 
 
Mounting, Wiring, and Setup 
 
 
IMPORTANT:  Before permanently mounting the 5800RL, 
perform the setup procedure described in the 
Setting Up 
the 5800RL section. 
 
1.  Remove the 5800RL's cover from the base (using a small 
flat head screwdriver, insert screwdriver’s tip in slot at top 
of the cover and twist). 
 
2.  Using the 5800RL base as a template, position in the 
desired location and mark the two mounting holes. See 
Figure 2 for mounting hole locations. 
3.  Attach the 5800RL base using the fasteners supplied. 
Screws and plastic anchors are suitable for a typical 
installation, but you may use any two fasteners that 
secure the base firmly to the mounting surface. 
4. Connect relay and power wiring to the 5800kRL’s 
terminals. Refer to Figure 3 for a typical relay application. 
The 5800RL can be powered from either an AC transformer 
or DC power supply external power source connected to 
terminals 7 and 8 (see Figure 3). 
Power source ratings and connections are as follows: 
Type Rating 
Connected 
to… 
Source 
Example 
AC 
9VAC, 15VA 
terminals 7 and 8 
Ademco 1332 
DC 9VDC, 
100mA 
N7703 
 
 
terminals 7 and 8 
or plugged into 
power connector. 
 
NOTE:  Use of power sources with higher or lower voltages 
may result in damage or failure to operate properly. Non-
ADEMCO power supplies may have connectors installed. 
Remove these connectors prior to attempting to connect 
power supply to 5800RL. 
 
TAMPER
SWITCH
2 - NO
3 - COM
4 - NC
5 - NO
6 - COM
7 - AC OR DC (+) IN
1 - NC
8 - AC OR DC (  ) IN 
RELAY A
RELAY B
5800RL-001-V1
LED
(RED)
LED
(YELLOW)
LED
(GREEN)
RF INTERFERENCE
LED (RED)
ANTENNA 2
ANTENNA 1
DIP
SWITCH
MOUNTING
HOLE
MOUNTING
HOLE
1 2 3 4 5 6
ON
OFF
 
Figure 2.  5800RL Diagram 
 
 
2 - NO
3 - COM
4 - NC
5 - NO
6 - COM
7 - AC OR DC (+) IN
1 - NC
8 - AC OR DC (  ) IN 
RELAY A
RELAY B
5800RL-005-V0
ANTENNA 2
SOUNDER
ANTENNA 1
1 2 3 4 5 6
ON
OFF
ADEMCO AD12612
AUX PWR SUPPLY
(12 VDC)
AC
IN
+
_
DC
OUT
1361
+
_
RED
BLA
CK
POWER SUPPLY
BACKUP
BATTERY 12VDC
+
PWR SUPPLY
XFMR
16.5VAC
 
Figure 3.  Typical Sounder Wiring Installation 
 
Setting Up the 5800RL 
Refer to RELAY and LED Operation section and DIP Switch 
(Figure 4) in order to set up the 5800RL as follows:
 
 
5.  Set DIP switches 3-6 (Figure 4) to the appropriate House 
ID (1-31). Make sure the House ID set by the DIP 
switches matches that entered in the LYNX control. 
6.  If module supervision and/or tamper protection is desired, 
program the 5800RL’s tamper/supervisory loop (1) as a 
zone and enroll its serial number. 
Note the following when enrolling: 
Zone Type = 5 (trouble by day/alarm by night) 
Input Type = 3 (RF) 
Loop Number = 1 
PLEASE GO TO THE BOTTOM RIGHT OF PAGE 2