Honeywell International Inc. 8DL5853-2 用户手册
Refer to Supplemental Information (next page) for complete descriptions of these installation steps
5-051-735-00BX
Page 1
®
)OH[*XDUG
5853 Wireless Glassbreak Detector Installation Instructions
5853 Glassbreak Detector Internal Parts
CR-123A
CR-123A
Mounting Hole
Mounting Hole
Batteries
Front Tamper Switch
LED Indicators
Microphone
Sensitivity Switches
Wall Tamper (behind battery)
Test Mode pads (on PCB)
Front Cover
Latch
Break out flash
for cover screw
2
1
ON
OFF
5853_001-v0
Connect Batteries
Remove pull tab to connect batteries
Select Mounting Location
Wall Mount
(Top View)
WallMount_001-V0
Avoid mounting within
0.3m (1 ft.) of a corner
0.3m (1 ft.) of a corner
CeilingMount_001-V0
Ceiling Mount: (Side View)
A
v
oid mounting within
0.3m (1 ft.) of a cor
ner
Set Sensitivity (Range)
SENS2
SENS1
CR-123A
CR-123A
SENS2
SENS1
5853_004-v0
SENS1 & SENS2 configure sensitivity
SENSITIVITY APPROXIMATE
RANGE
SENS1 SENS2
MAX
25 ft (7.6m)
OFF OFF
MEDIUM
15 ft (4.6m)
ON OFF
LOW
10 ft (3m)
OFF ON
LOWEST
5 ft (1.5m)
ON ON
Enroll Detector
Refer to text and control panel's installation
instructions.
instructions.
When programming the transmitter, specify:
•
Input Type = 3 (Supervised RF)
•
Loop Number = 1
Mount Detector
•
Use mounting holes as a template to mark
mounting locations on ceiling or wall.
mounting locations on ceiling or wall.
•
If using the optional wall tamper, remove
the batteries, then mark the rear tamper
location through its mounting hole.
location through its mounting hole.
•
Mount detector using appropriate hardware.
•
Close detector cover when finished.
CR-123A
CR-123A
SENS2
SENS1
5853_003-v0
Optional Tamper Screw
#6 x 1-1/2"
#6 x 1"
#6 x 1-1/2"
Test Detector Installation
Enter Test Mode using GBS-7 (see text). To enter
Test Mode manually, short Test Mode pads (as below).
Test Mode manually, short Test Mode pads (as below).
CR-123A
CR-123A
SENS2
SENS1
SENS2
SENS1
5853_005-v0
TEST
TEST
Install Cover Screw (optional)
5853_006-V0
2.2 mm (#4) scre
w,
6 mm (1/4-in.) long
ON
OFF