Preliminary - 6 September 2002
 
INSTALLING THE 6160RF
 
Locate the 6160RF in an area and at a height where it is 
convenient for user operation. The 6160RF must be at 
least 10 ft from the control panel to ensure proper 
operation of the RF receiver. 
Mounting And Wiring 
The 6160RF has terminal blocks for connection to power 
and data wires, and relay contact wires. Removing the 
keypad’s case back accesses these terminal blocks. 
The 6160RF can be surface mounted directly to walls, or 
to a single- or double-gang U.S./Italian style electrical box. 
Follow these steps to mount and wire the keypad: 
1.  Detach the case back by pushing up into one of the two 
slots at the bottom of the keypad with the blade of a 
small screwdriver (this will push in the release snap), 
then pull that side of the case back away. Repeat for 
the other side. Refer to Figure 1 for location of the case 
back release snaps. 
 
ARMED
READY
MOUNTING
RELEASE
SNAPS
NOTE:
TO REMOVE REAR COVER
PUSH IN THE TWO MOUNTING
SNAPS LOCATED ALONG THE 
BOTTOM OF THE KEYPAD
AND LIFT COVER UP.
6164RF-003-V0
 
Figure 1.  Removing the Case Back 
2.  Pass the wiring from the control panel through the 
opening in the case back. (see the control panel’s 
instructions for proper run lengths.)  
a.  If surface wiring is being used, wiring may be 
routed through the top or the bottom left-side 
breakout in the case back. See Figure 2. The 
breakouts must be punched out using a screwdriver 
before mounting the case back.  
b.  If desired, wires may be strain-relieved to the wire 
tie point on the inside of the case back with a tie 
wrap (not supplied).
 
3.  Mount the case back to a wall or to an electrical box 
using the 25mm-long self-tapping screws supplied 
(mollies for drywall are not supplied).  
Note: If you wish to tamper-protect the keypad for removal from the 
wall, use an additional mounting screw in the tamper hole in 
the case back (see Figure 2 for location). 
4.  Connect the power and data wires from the control 
panel to the terminals on the 6160RF as indicated 
Figure 3 and Table 1. 
 
G
6160RF-002-V0
Y +
TAMPER
SWITCH
WIRING TERMINALS
(TO CONTROL PANEL)
+ +
+ +
 
Figure 3 - 6160RF Wiring Details 
 
Table 1 - Wiring Table 
Keypad 
Control Panel 
Wire Color 
 G 
Data In 
Green 
-Aux Pwr (GND) 
Black 
+Aux Pwr 
Red 
y
 Y 
Data Out 
Yellow 
 
5. Re-attach the keypad  to the mounted case back. 
Attach the top of the keypad first, and then press the 
bottom section down until it snaps into place securely. 
6. Peel off protective film on the LED panel and install the 
keypad labels as required. 
 
6160RF PROGRAMMING 
Entering Program Mode 
Press the [1] and [3] keys simultaneously for a few seconds within 30 seconds after applying power or within 30 seconds after 
removing the case back.  The current keypad address 
CON ADDRESS = XX
 will be displayed. Press the [
] key. 
Programming Operations 
Once you have entered the Program mode, you may advance between prompts by pressing the [✳] key. This will also store 
displayed information. 
 
Programming the 6160RF 
Note: Refer to the control panel’s installation instructions for the acceptable keypad and receiver addresses. 
 
• 
If you are using a wireless key in High-Security mode (e.g.;5804E) in the control panel, it will occupy one of the devices in the 
6160RF. 
• 
When operating the system in High-Security mode, only encrypted wireless keys will function.