Data Field Descriptions 
 
49 
Split/Dual Reporting 
 
 
To Primary 
To Secondary 
0 = All reports 
None, unless primary 
 
 
 fails, then all 
1 = Alarms, Restore, Cancel* 
Others 
2 = All except Open/Close, Test 
Open/Close, Test 
3 = Alarms, Restore, Cancel 
All 
4 = All except Open/Close, Test 
All 
5 = All reports 
All 
 
To Primary 
To Paging Number 
6 = All reports except Open/Close  Alarms, Open/Close ‡, 
  
 
Troubles 
7 = All reports 
Alarms, Troubles 
8 = All reports 
Alarms, Open/Close ‡, 
  
 
Troubles 
9 = All reports except Open/Close  Open/Close ‡ 
 
 
To Primary 
To Follow Me System 
  
 
Phone 
Number 
10=All reports except Open/Close  Alarms, Open/Close ‡, 
  
 
Troubles 
11 = All reports 
Alarms, Troubles 
12=All reports 
Alarms, Open/Close ‡, 
  
 
Troubles 
13=All reports except Open/Close  Open/Close ‡ 
*Recent close report is sent to primary number 
‡ Will report Users 0, 5-8, and, if using wireless button-type 
devices, will report the zone number of the arm or disarm 
button 26-33. All other zones and users are not reported.
 
This field is used to select a reporting option as follows: 
Enter:  0 - 5 when reporting to telephone receivers. 
 
6 - 9 when reporting to a pager is desired. 
 
10 - 13 when reporting to an auxiliary telephone receiver. 
 
Pager Report Format 
Options 6-9 send reports to the primary phone number, in a format defined 
in Field 
48, and send reports to a pager, which has its phone number 
entered as the secondary phone number in Field 
42.  The pager report is a 
7-digit code, with optional 16-digit prefix, in the following format:  
AAAAAAAAAAAAAAAA-EEE–00NN  where: 
AAA =  Optional 16 digits for PIN number, etc. See Field 
88 for full 
description of these characters. 
EEE =  3-digit Event Code as follows: 
911 =   Alarm (NN = zone number) 
101 =   Open, system disarmed (NN = user no.) 
102 =   Close, system armed (NN = user no.) 
811 =    Trouble (NN = zone no.) 
00  = 
Always displayed before 2-digit user/zone no. 
NN = 
2-digit user number or zone number, depending on the type of 
event (EEE) that occurred.  
 
Follow Me System Report Format 
Options 10-13 send reports to the primary phone number, in a format 
defined in Field 
48, and sends voice message to the secondary phone 
number entered in Field 
42. 
The message is a repeatable system status announcement. If the manual 
paging option has been programmed in Field 
87, the message will repeat 
“system, system…..”. 
 
The message can be terminated by pressing any key on the telephone 
keypad. 
 
50
 
Burglary Abort Window 
0 =No abort window 
1 = 15-second abort window 
2 = 30-second abort window 
3 = 45-second abort window 
 
SIA Abort Window time options: 1 = 15 secs; 2 = 
30 secs; 3 = 45 secs 
0 = refer to Entry delay set in field *35 
 
 
This provides the option for an Abort Window for Burglary zone types that 
report to the central station. This feature allows time for the subscriber to 
avoid a false alarm transmission.  This feature does not apply to zone type 9 
alarms (Supervised Fire) or to 24-hour zone types 6, 7, and 8 (silent panic, 
audible alarm, auxiliary alarm), which are always sent as soon as they occur.
 
SIA Guidelines: must be set to a minimum of 15 seconds 
 
UL/SIA The sum of the burglary abort window entered in ✻50 and the 
entry delays entered in either Field ✻35 or ✻36 should not exceed 
1 minute. 
Note: The control  validates the data entered in this field. If the selection is 
not valid the control will emit a single long beep indicating that the 
selection has been rejected. The control replaces the selection with 
the default value which is displayed on the keypad. 
51
 
Periodic Test Report 
0 = no test report 
2 = weekly 
1 = once every 24 hrs  3 = once every 30 days 
 
Test report code entered in field 
64 is sent. 
52
 
First test Report Offset 
0 = 24 hrs after exit program mode or download 
1 = 6 hours after exit program mode or download 
2 = 12 hrs after exit program mode or download 
3 = 18 hrs after exit program mode or download 
 
This is the time to first report from programming or downloading. 
53
 
Sescoa/Radionics Select 
0 = Radionics (0–9, B–F reporting) 
1 = SESCOA (0–9 only reporting) 
 
Select 0 for all other formats. 
54 
Lack of Usage Notification 
0 = Disabled 
4 = 90 days   
1 = 1 day 
5 = 180 days 
2 = 7 days 
6 = 365 days 
3 = 27 days 
 
Note: There will be no local annunciation indicating that 
this report has been sent to the Central Station. 
If enabled, notifies the central station if an end user is not operating their 
security system by sending a System Inactivity report 654.  The report will 
be sent only to the Primary phone number and only if Contact ID® format 
was selected. 
Note: The report will follow the 
49 = 0 rules, no matter which selection 
was made in 
49.