2.6.2. 
Figure 2-5. Shows the installation of the shock tube onto the igniter tip when 
preparing for use.  Take care when handling the shock tube to prevent the incursion of 
debris or moisture into the tube. Keep open tube ends capped except during 
preparation for use.  Keep the tip needle clean and dry. Replace the tip every 200 shots 
or if misfiring occurs.  
WARNING  
Do not touch the igniter tip jacks on the Radio Shock Tube Initiator 
(RSTI) when armed or firing. Lethal voltages may be present. 
 
1.  Make a fresh cut with a sharp knife removing the last 6 inches of shock tube.  
 
Figure 2-5 Shock Tube Igniter Tip 
 
2.  Insert the shock tube through the guide hole on the tip as shown in Figure 2-5. 
The guide hole secures the tube to the tip and prevents pulling out. 
3.  Insert the tube into the center hole on the flat side. Feed the tube through the 
hole observing the side view hole. The tube should slide onto the igniter needle 
until the needle is no longer visible and the tube is resting against the plastic tip 
housing.