5. OPERATIONAL  PROCEDURES. 
WARNING 
Use of this system and its components must be restricted to personnel 
qualified and experienced in the field of explosives and detonating devices. Under no 
circumstances shall untrained personnel attempt to use this manual as a text for self-
teaching. 
WARNING 
Employ standard blasting system safety standards when using this 
equipment with explosives. 
CAUTION 
All units must be thoroughly tested and the batteries fully charged prior to 
operational use. 
5.1. 
READY THE SYSTEM AT SITE. 
5.1.1. 
Remote Units.  Select the number of Remote Units required for the operation.  
Remove the dust cover from the antenna / battery charger connector.  Install the 
Antenna Assembly on to the antenna / battery charger connector.  This will turn on the 
Remote Unit.  The yellow ON/LOW BATT light and green SAFE light will be turned on.  
The green SAFE light will be on whenever the Remote Unit is turned on and it is 
disarmed.  In the disarmed state, the firing capacitor charge circuit is disabled, the 
binding posts are electrically isolated from the firing capacitor, and the binding posts are 
shunted to each other.  If the yellow ON/LOW BATT light is flashing, the Remote Unit 
battery is low and should be recharged before use. 
WARNING 
Do not connect a blasting cap to a Remote Unit unless the green SAFE 
light is on, the red ARMED light is off, and the yellow ON/LOW BATT light is on steady.  
This indicates there is no voltage on the binding posts, the binding posts are electically 
isolated from the firing capacitor, the binding posts are shunted to each other, and the 
battery is not low. 
5.1.2. 
Open and close the vent on each Remote Unit and the Controller Unit to 
equalize the case pressure.  Unscrew the vent, one revolution, to open. 
5.1.3. 
Remove the dust cover from the antenna / battery charger connector of the 
Controller Unit.  Install the Antenna Assembly on to the antenna / battery charger 
connector.  This will enable the keypad on the Controller Unit. 
WARNING 
Do not use the Controller Unit within 100 feet of explosives, blasting 
caps, or wires leading to them. The controller signal is 5 watts, which can cause 
detonation of caps if within 100'. The 5 watt controller complies with the Recommended 
Table of Distances established by the Institute for the Makers of Explosives (IME) when 
placed beyond 100 feet of explosives.