Honeywell International Inc. 9PGTPL-100A 用户手册

下载
页码 180
Page 1002
1 Mar 2006
34-45-54
MAINTENANCE MANUAL
TPL-100A Processor / Part No. 940-0530-001
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
Table 1001.   MILACAS-FR System Maintenance Test (IBIT) 
Action
Initial 
Indications
 IBIT Status
Pass
Fail
Corrective 
Action
With power on 
start test from 
MCD 
Maintenance 
Page.
"
SKE: IN 
PROGRESS
"
  
is displayed on 
MCD followed 
by:
"
IN TEST
"
 
displayed in test 
pattern on MFD 
MCD 
displays the 
reported SKE 
IBIT status:
"
PASS
"
"
RT
"
"
UA
"
"
LA
"
"
GU
"
"
GE
"
"
SYN
"
"
SYS
"
CAWS Voice 
message:  
"
TCAS 
System Test 
OK
"
MCD 
displays 
"
PASS
"
1. CAWS Voice
 Message:  
"
TCAS System 
Test Fail
"
 
2. MFD 
"
IN 
TEST
"
 
annunciation 
replaced by 
"
TCAS FAIL
"
Perform 
MILACAS-FR 
Processor  
self-test using 
Front Panel to 
verify failure and 
source of fault 
(MILACAS-FR 
or External 
Fault) Refer to 
paragraph 1.F
Table 1002.   MCD LRU Fault List Display
MCD LRU Avionics 
Fault List
Failure Cause
Corrective Action
SKE-RT
Faulty  processor 
Perform MILACAS-FR Processor self-test using front 
panel to verify failure and source of fault. Refer to 
paragraph 1.F.
Remove and replace faulty MILACAS-FR Processor.
SKE-U_ANT
SKE-L _ANT
Faulty  antenna 
Perform MILACAS-FR Processor self-test using front 
panel to verify failure and source of fault. Refer to 
paragraph 1.F.
Remove and replace antenna,
remove and replace circuit breaker
or remove and replace/repair aircraft wiring.
Refer to TPL-100A CMM 012-0794-001.
SKE-GUID_DATA
Faulty  external 
LRU or wiring
Perform MILACAS-FR Processor self-test using front 
panel to verify failure and source of fault. Refer to 
paragraph1.F.
Remove and replace faulty LRU, 
remove and replace circuit breaker
or remove and replace/repair   
aircraft wiring. Refer to TPL-100A CMM 012-0794-001.