Honeywell International Inc. 9PGTPL-100A 用户手册
Page 1002
1 Mar 2006
34-45-54
MAINTENANCE MANUAL
TPL-100A Processor / Part No. 940-0530-001
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
Table 1001. MILACAS-FR System Maintenance Test (IBIT)
Action
Initial
Indications
IBIT Status
Pass
Fail
Corrective
Action
With power on
start test from
MCD
Maintenance
Page.
start test from
MCD
Maintenance
Page.
"
SKE: IN
PROGRESS
"
is displayed on
MCD followed
by:
MCD followed
by:
"
IN TEST
"
displayed in test
pattern on MFD
pattern on MFD
MCD
displays the
reported SKE
IBIT status:
displays the
reported SKE
IBIT status:
"
PASS
"
"
RT
"
"
UA
"
"
LA
"
"
GU
"
"
GE
"
"
SYN
"
"
SYS
"
CAWS Voice
message:
message:
"
TCAS
System Test
OK
OK
"
MCD
displays
displays
"
PASS
"
1. CAWS Voice
Message:
Message:
"
TCAS System
Test Fail
"
2. MFD
"
IN
TEST
"
annunciation
replaced by
replaced by
"
TCAS FAIL
"
Perform
MILACAS-FR
Processor
self-test using
Front Panel to
verify failure and
source of fault
(MILACAS-FR
or External
Fault) Refer to
paragraph 1.F
MILACAS-FR
Processor
self-test using
Front Panel to
verify failure and
source of fault
(MILACAS-FR
or External
Fault) Refer to
paragraph 1.F
Table 1002. MCD LRU Fault List Display
MCD LRU Avionics
Fault List
Failure Cause
Corrective Action
SKE-RT
Faulty processor
Perform MILACAS-FR Processor self-test using front
panel to verify failure and source of fault. Refer to
paragraph 1.F.
panel to verify failure and source of fault. Refer to
paragraph 1.F.
Remove and replace faulty MILACAS-FR Processor.
SKE-U_ANT
SKE-L _ANT
SKE-L _ANT
Faulty antenna
Perform MILACAS-FR Processor self-test using front
panel to verify failure and source of fault. Refer to
paragraph 1.F.
panel to verify failure and source of fault. Refer to
paragraph 1.F.
Remove and replace antenna,
remove and replace circuit breaker
or remove and replace/repair aircraft wiring.
Refer to TPL-100A CMM 012-0794-001.
remove and replace circuit breaker
or remove and replace/repair aircraft wiring.
Refer to TPL-100A CMM 012-0794-001.
SKE-GUID_DATA
Faulty external
LRU or wiring
LRU or wiring
Perform MILACAS-FR Processor self-test using front
panel to verify failure and source of fault. Refer to
paragraph1.F.
panel to verify failure and source of fault. Refer to
paragraph1.F.
Remove and replace faulty LRU,
remove and replace circuit breaker
or remove and replace/repair
aircraft wiring. Refer to TPL-100A CMM 012-0794-001.
remove and replace circuit breaker
or remove and replace/repair
aircraft wiring. Refer to TPL-100A CMM 012-0794-001.