RELM Communications Inc SRU50ABC 用户手册

下载
页码 38
S Series Repeater USER MANUAL
©RELM Communications Inc.  Revision 1.0
36
DIP Switch 2 User Function Select
Switch Number
Description
Switch 1
PTT Delay
Inserts a 100mS delay for the Transmitter RF rise time. Must be
selected when using a coaxial simplex changeover relay to prevent
switching RF power.
Switch 2
Simplex On
Selects simplex mode of operation.
Switch 3
Tx Timer On
Transmitter is disabled after 2 minutes continuous use.
Switch 4
Repeater On
Selects automatic Receiver to Transmitter repeater function. The
Transmitter will also have a 2 second ‘hang time’.
Switch 5
Tx VCO Cont
Enables the Transmitter’s VCO to operate continuously in ‘hot
stand by’ mode. This speeds up the Transmitter’s rise time to 4mS.
Caution: Low level signal leakage may affect the receiver’s
performance if the Transmitter is on the same frequency.
Switch 6
Tx FSK
Generates an FSK test signal. Not normally used.