UTC Fire & Security Americas Corporation Inc 772-DWS 用户手册
1
Door/Window & Long Life Door/Window Sensors
ITI Part Nos. 60-362 & 60-641
ÃÌ>>ÌÊÃÌÀÕVÌÃ
Document Number: 466-1022 Rev. D PRELIMINARY
October 2000
October 2000
*Ài>ÀÞÊ£äÉÓÎÉ
8867g01a.ds4
Product Summary
The Door/Window Sensor (60-362) and Long Life Door/
Window Sensor (60-641) can be installed on doors, win-
dows, or virtually anything that opens and closes. During
normal operation, the sensors transmit open (TRIP) and
close (RESTORE) signals to the panel. The sensors also
send a supervisory signal to the panel every 64 minutes.
Window Sensor (60-641) can be installed on doors, win-
dows, or virtually anything that opens and closes. During
normal operation, the sensors transmit open (TRIP) and
close (RESTORE) signals to the panel. The sensors also
send a supervisory signal to the panel every 64 minutes.
Sensors transmit open and close signals to the panel when a
magnet (mounted near the sensor) is moved away from or
closer to the sensor.
magnet (mounted near the sensor) is moved away from or
closer to the sensor.
The sensors are powered by a 3.6-volt lithium battery.
Ìi
The Long Life Door/Window Sensor battery cannot be
replaced by installers or users. If you receive a low
battery report, you must return the sensor to ITI for
replacement.
replaced by installers or users. If you receive a low
battery report, you must return the sensor to ITI for
replacement.
Tools Needed
q #6 flathead screws or 18-gauge brads
q Screwdriver or brad driver
q Small wire cutters
q Sensor and magnet spacers (optional)
q Screwdriver or brad driver
q Small wire cutters
q Sensor and magnet spacers (optional)
Installation Guidelines
q Keep all sensors within 100 feet of the panel.
q Mount the sensor on the door frame and the magnet on
q Mount the sensor on the door frame and the magnet on
the door. If the sensor is to be used on double doors,
mount the sensor on the least used door and the magnet
on the other door.
mount the sensor on the least used door and the magnet
on the other door.
q Mount sensors with screws or brads, not double-sided
tape.
q Place sensors at least 5 inches above the floor to avoid
damaging them.
q Use spacers (not included) to keep sensors and magnets
away from metal or metallic surfaces such as foil wall-
paper.
paper.
Door/Window Sensor Spacers
White: ITI Part #60-189
Brown: ITI Part #60-191
Magnet Spacers
White: ITI Part #60-188
Brown: ITI Part #60-190
White: ITI Part #60-189
Brown: ITI Part #60-191
Magnet Spacers
White: ITI Part #60-188
Brown: ITI Part #60-190
q Remove the internal reed switch not being used.
q Avoid mounting sensors in areas with a large quantity
q Avoid mounting sensors in areas with a large quantity
of metal or electrical wiring, such as a furnace or utility
room.
room.
q Avoid mounting sensors in areas where they will be
exposed to moisture.
q Avoid mounting sensors in locations where the operat-
ing temperature (10° to 120° F) will be exceeded.
1/"
Do not remove the jumper from the Long-Life Door/
Window Sensor circuit board! The sensor cannot work
without the jumper.
Window Sensor circuit board! The sensor cannot work
without the jumper.
Installation
1/"
You must be free of all static electricity when handling
electronic components. Touch a grounded, bare metal
surface before touching a circuit board or wear a
grounded wrist strap.
electronic components. Touch a grounded, bare metal
surface before touching a circuit board or wear a
grounded wrist strap.
1.
Decide if the sensor should be mounted horizontally or
vertically by locating the alignment marks on the sen-
sor and magnet plastic (see Figure 1.)
vertically by locating the alignment marks on the sen-
sor and magnet plastic (see Figure 1.)
The marks indicate reed switch locations. Each sensor
uses only one of the two switches. You will remove the
unused one in step 4.
uses only one of the two switches. You will remove the
unused one in step 4.
Figure 1. Alignment marks
2.
Remove the sensor cover by squeezing the cover ends
firmly to release the tab on the cover from the slot on
the sensor base.
firmly to release the tab on the cover from the slot on
the sensor base.
3.
Remove the circuit board from the sensor base by pull-
ing back the plastic tab and lifting the battery to release
the circuit board.
ing back the plastic tab and lifting the battery to release
the circuit board.
SENSOR END VIEW
SENSOR SIDE VIEW
MAGNET
ALIGNMENT MARKS
ALIGNMENT MARK
8867G03A.DS4
'RRU:LQGRZ /RQJ
/LIH'RRU:LQGRZ
6HQVRUV