Andrew Wireless Innovations Group BCEL-FAST719 用户手册

下载
页码 30
 
MN021-01 
Page 17  of 28
 
 
OPTICAL LOSS 
OPERATION 
ALARM 
SEVERITY 
0 dB 
AGC working, constant RF gain  
none 
NONE 
< 3dB 
AGC working, constant RF gain 
none 
NONE 
< 5 dB 
AGC not working, RF gain 
decreases according to 2dB 
electrical per 1dB optical  
AGC out of range: 
red LED flashes  
MINOR 
> 5 dB 
AGC not working, the optical 
signal is too low, the receiver is 
automatically switched off in 
order to reduce the unwanted 
noise to the system. 
Optical power too 
low: red LED 
fixed, relays 
alarmed. 
MAJOR 
 
 
11. Alarms and settings  
11.1.  
Remote unit LEDs 
The TFAF is fully managed and supervised by the local microprocessor. The alarms are fully 
managed by software according to different severity levels, and reported as local visual alarms 
(LED’s) and on the data link to the local unit. 
 
There are 2 LED on the Local unit, one red alarm LED is related to optical link and internal 
failures, one green LED is for the power supply. 
 
 
 
 
 
 
 
 
 
Figure 12  Remote Unit TFAF LED’s 
 
 
REMOTE ALARM DESCRIPTION 
LED 
STATUS 
SEVERITY 
UL AGC out of range 
RED 
Flashing 
MINOR 
UL optical power too low 
RED 
Fixed 
MAJOR 
DL RF amplifier 1  
RED 
Fixed 
MAJOR 
DL RF amplifier 2 
RED 
Fixed 
MAJOR 
Antenna disconnected (DC loop) 
RED 
Flashing 
MINOR 
External 1 
RED 
Fixed 
MAJOR 
External 2 
RED 
Fixed 
MAJOR 
11.2.  
External alarms 
Two external alarm contacts are provided. These contacts are open under non-alarm condition. 
 
 
 
 
 
 
 
 
 
Figure 13  Remote Unit TFAF Alarm Connectors