6. Due to power dissipation, the Remote Unit may reach a very high
temperature. Ensure sufficient airflow for ventilation. Above and below the
unit a minimum distance of 300 mm to ceiling, floor, etc. has to be kept.
Also observe the instructions in the individual mounting procedures.
unit a minimum distance of 300 mm to ceiling, floor, etc. has to be kept.
Also observe the instructions in the individual mounting procedures.
7. For outdoor installations, the pre-mounted front cover must be installed.
8. For indoor installations where the ambient temperature can reach above
40°C, the cover has to be removed.
9. When connecting and mounting the cables (RF, optical, mains, ...) ensure
no water can penetrate into the unit through these cables.
If any different or additional mounting material is used, ensure that the mounting
remains as safe as the mounting designed by the manufacturer. Ensure that the
static and dynamic strengths are adequate for the environmental conditions of the
site. The mounting itself must not vibrate, swing or move in any way that might cause
damage to the Remote Unit.
3.1.2. Wall and Pole Mounting
Wall and pole mounting equipment for the unit is available. For the according
mounting please refer to the mounting plan (drawing) that is part of the delivery.
figure 3-1 Wall mounting
figure 3-2 Pole mounting