Andrew Wireless Innovations Group RPT-MR701 用户手册

下载
页码 76
User’s manual for Repeater MR801B Power
M0067A0A.doc
Id.-No 151111
Page 46
02-JUNE-99
7 Setting to work
7.1 Preparation
Note:
It is not allowed to operate the Repeater without termination of the 
antenna connections! The termination can be performed by the antenna 
connection as well as a dummy load or the 50-Ohm-terminated connection
of a measuring instrument.
Before bringing the Repeater system into service it is necessary to measure the antenna
isolation. The Repeater system has its maximum available gain when the attenuation is set to
zero. On site the maximum allowed gain is 15 dB less than the value of the antenna isolation.
In order to check the function of the Repeater system on site it is advisable to operate the
Repeater system with 50 Ohm termination. This makes it possible to set the necessary gain
and to test the set value without the necessity of transmitting on air.
In order to perform settings the Repeater has to be opened. Please, ensure not to damage the
seals, which are on the modules situated on the RF modules inside of the Repeater, because
this would lead to risk the success of warranty claims.
After taking the Repeater into service following signals occur during the boot process.
Internal
LED L1
Internal
LED L2
Internal
LED L3
Cause
green
red
green
red
green
-
-
-
-
l
l
Power on state,
Software boot starts
l
l
Flashes
red short
time
l
l
Flashes red
short time
l
l
Software boot starts
l
l
l
l
l
l
Software is running
table 7-1 LED indication