Andrew Wireless Innovations Group RPT-MR701 用户手册

下载
页码 76
User’s manual for Repeater MR801B Power
M0067A0A.doc
Id.-No 151111
Page 52
02-JUNE-99
7.2.3 Settings via modem
The Repeater can be equipped with a modem. If so, the repeater will be delivered with a
preset init string. This init string was used for internal tests. In case no connection can be
established check the local conditions and change the init string if necessary.
The following list contains the description of the AT commands:
&F
Sets modem to factory configuration
E0
Echo OFF
S0=1
Auto answer ON; the GSM module / M1 modem goes off-
hook after the first ringing signal.
S7=60
Waiting time for connection after dialing; permissible values
are from 0 ... 60.
B13
Setting to 9600 bps asynchronous mode
\ N6
Auto reliable operation
\ N0
Standard operation, no error correction
+CBST=7,0,1
Set bearer service type to 9600 bps. Non-transparent
connection (uses RLP)
X3
Not waiting for dial tone; usually used at PABX.
*P1
Switch ON phone
&K4
Enables XON / XOFF flow control
table 7-7 List of AT commands