Andrew Wireless Innovations Group RPT-NODEC1943 用户手册

下载
页码 102
 
User’s Manual for Node C Network Elements
 
Page 20 
PRELIMINARY M0121A1A_uc.doc
 
3.2 ELECTRICAL 
INSTALLATION 
3.2.1 General 
 
Read the health and safety warnings in chapter 1.2 Health and Safety Warnings
1.  This unit contains dangerous voltages. Loss of life, severe personal 
injury or property damage can be the result if the instructions contained 
in this manual are not followed. 
2.  It is compulsory to ground the unit before connecting power supply. A 
grounding bolt is provided on the cabinet to connect the ground bonding 
cable. 
3. Although the unit is internally protected against overvoltage, it is 
strongly recommended to earth the antenna cables close to the unit’s 
antenna connectors for protection against atmospheric discharge. In 
areas with strong lightning it is strongly recommended to insert 
additional lightning protection. 
4.  Hard wired installation of mains supply for the unit requires an easily 
accessible separation device in the mains circuit. 
5.  Make sure that an appropriate circuit breaker and an overcurrent limiting 
device are connected between mains and the unit. 
6.  A connection of mains supply to a power socket requires the power 
socket to be nearby the unit. 
7.  The unit might be supplied from IT mains. (The maximum nominal line to 
line voltage must not exceed 400VAC). 
8. Incorrectly wired connections can destroy electrical and electronic 
components. 
9. To avoid corrosion at the connectors caused by electrochemical 
processes, the material of the cable connectors must not cause a higher 
potential difference than 0.6V (see electrochemical contact series). 
10. It is sufficient to tighten the 7/16 or N antenna connector hand-screwed. 
Any use of a tool (e.g. pair of pliers) might cause damage to the 
connector and thus lead to malfunctioning of the unit. 
11. For unstabilized electric networks which frequently generate spikes, it is 
advised to use a voltage limiting device. 
12. The unit complies with the surge requirement according to EN 61000-4-5 
(fine protection), however, it is recommended to install an additional  
medium (via local supply connection) and/or coarse protection (external 
surge protection) depending on the individual application in order to 
avoid damage caused by overcurrent. 
13. Observe the labels on the front panels before connecting any cables.