Andrew Wireless Innovations Group RPT-NODEC843 用户手册

下载
页码 102
 
User’s Manual for Node C Network Elements
 
Page 86 
 M0121A1A_uc.doc
 
 
When the battery is charging, an LED on the module turns on. When the battery is 
fully charged, the LED will switch off. 
 
The location of the battery backup parts are illustrated in figure 6-2 Location of 
battery backup
.  
 
For technical data of the battery backup module refer to chapter 7.2.3 Specifications 
for Optional Equipment

 
5.4.2 PSU 
Redundancy 
 
The Node C Interface Unit may be equipped with two power supplies. This 
guarantees full power redundancy. The PSUs are interconnected by a current control 
line for current load sharing with a ratio of approx. 50% to each supply. 
 
Currently the PSU redundancy option is only available for Node C x37. 
 
5.4.3  High Rejection Filter 
 
This software option provides a highly sophisticated filter feature that can be 
controlled via the “Technician Setup” menu of the web page (see figure 4-7 
Technician Setup menu
).