Bogen V150 产品宣传页

下载
页码 2
The amplifier shall be a Bogen Power Vector Amplifier,
Model V35, V60, V100, V150, or V250. The amplifier shall
be compatible with both high- (70/25V) and low- (4/8-
ohm) impedance speakers, with the capability of 35, 60,
100, 150, or 250 watts, respectively. 
The amplifier shall provide 8 module bays for plug-in input
modules with two of the bays also capable of handling
plug-in signal-processing output modules. There shall be
4 levels of priority available between all modules.
Each of the 8 module bays shall have an associated inde-
pendent volume control. Each independent volume con-
trol shall have a signal/clip LED to indicate signal condi-
tion. Each amplifier shall also include bass and treble con-
trols, as well as a motorized master volume control, which
can be remotely operated using the RVCP accessory
(sold separately).
For larger applications, the amplifier shall be able to
bridge to another Power Vector amplifier or mixer using a
built-in bridging jack and mute terminals. This connection
shall effectively increase the number of inputs.
An 11-segment LED output level meter will register either
the average or peak level of the amplifierʼs output level, as
selected by an Average/Peak switch. Each Power Vector
amplifier shall have a Tone Control Bypass switch and a
Low-Cut Filter switch, both located on the rear of the
amplifier in module bay 6.
A lockable switch will permit the selection of transformer-
coupled output or direct output for speaker connections.
Signal-processing Insert jacks (RCA connectors) will
allow external equipment to be inserted between the pre-
amp output and the power amp input.
Each model will have a Pre-EQ, unbalanced (RCA jack),
buffered output whose signal is post all volume controls,
tone controls, and output module signal-processing, but
before (pre-EQ) any external signal-processing equip-
ment connected to the Insert jacks.
Each amplifier will have bridging in/out capability and indi-
vidual access to internal module priority buses for easy
connection of multiple amplifiers or mixers in a system.
Each amplifier will include a 500W maximum, unswitched
AC power receptacle.
The amplifier shall fit into a 19" rack and fit in two rack
spaces (2 RU). It shall allow the attachment of feet for
tabletop placement. Each model shall measure 17-1/4" W
x 3-7/8" H x 14-3/4" D. The V35 shall weigh 22 lb., the
V60 - 26 lb., the V100 - 28 lb., the V150 - 31 lb., and the
V250 - 32 lb.
Architect and
Engineer
Specifications
50 Spring Street, Ramsey, New Jersey 07446, U.S.A.
Tel. 201-934-8500 • Fax: 201-934-9832
www.bogen.com
Power Output (RMS):
V35
V60
V100
V150
V250
Rated:
35W
60W
100W
150W
250W
Typical @ 1 kHz:*
45W
85W
140W
200W
340W
Frequency Response
Transformer:
45 Hz to 20 kHz; +0/-2 dB
Direct:
20 Hz to 20 kHz; +0/-1 dB
Distortion
Transformer:
< 0.5%**
Direct:
< 0.1%** (.05 typical @ 1 kHz)
Signal-to-Noise
Fundamental:
-94 dB
With SAX1R Module:
-70 dB
With MIC1S Module:
-60 dB
With TEL1S Module:
-70 dB
Tone Controls
Bass Frequency:
@100 Hz (+/- 10 dB minimum)
Treble Frequency:
@10 kHz (+/- 10 dB minimum)
Low Cut Frequency:
@125 Hz (-6 dB/octave)
Sensitivity
0.4V (at backplane connector)
Output Regulation:
2 dB or better, no load to full load
Output Impedance
Transformer-Coupled:
70V, 25V, 8 ohms (bal or unbal)
Direct Coupled:
4 ohms (minimum)
Thermal Emissions:
V35
V60
V100 V150 V250
(BTU/hr.)
174.2 204.9 495.2 696.7 911.9
Inserts
Insert "OUT" Level:
1VRMS (@FRP)
Insert "OUT" Impedance:
50 ohms maximum
Insert "IN" Sensitivity:
1VRMS
Insert "IN" Impedance:
10k ohms minimum
Bridging In/Out
Bus Level:
250 mVRMS (@FRP)
Bus Impedance:
10k ohms maximum
Pre-EQ Output
Output Level:
4VRMS (@FRP)
Output Impedance:
50 ohms maximum
AC Power Receptacle:
500 watts maximum power, unswitched
AC Voltage:
120V AC, 60 Hz
AC Current:
V35
V60
V100 V150 V250
0.6A
1.3A
2.0A
3.5A
5.5A
Product Weight (lb.):
V35
V60
V100 V150 V250
22
26
28
31
32
Dimensions:
17-1/4" W x 3-7/8" H x 14-3/4" D 
(all models)
Technical
Specifications
* Typical, @1 kHz/0.1% THD/4-ohm direct      ** THD+N, Maximum, Full bandwidth @ FRP      † Referenced to FRP output level, 20 Hz to 20 kHz bandwidth limited