Fuzhou Ewetime Electronic Co. Ltd TX9 用户手册

下载
页码 2
EWT 8280A-1 INSTRUCTION MANUAL
1
2
3
6
4 5
7 8 910 11
12 13 14
15
24
25
26
27
28
29
16
17 18
19 20 21
22
23
30
31
32
33
38
37
36
35
34
1. Indoor temperature alert
2. Indoor temperature / humidity
3. Tendency indoor temperature
4. Display low battery indicator
5. Indoor temperature/humidity 
    MAX/MIN records
6. Icons weather forecast
7. Trend of barometer display
8. Outdoor sensor signal strength
9. Outdoor temperature alert
10. Outdoor temperature / humidity 
      external sensor
11. Channel external sensor
12. Tendency outdoor temperature
13. Sensor low battery indicator
14. Outdoor temperature/humidity 
      MAX/MIN records
15. Tendency indoor humidity
16. Indoor comfortable level
17. Weekday
18. Time display
19. Alarm and snooze icons
MAIN FEATURE:
a) 6 Keys:      ,      ,       ,     ,▲,▼        
b) RCC receive form: DCF
c) Barometric pressure display
d) Weather forecast: Sunny, Partly sunny, Cloudy, Rainy, Stormy and Snowy.
e) Low Battery indicator for outdoor sensor and station
f) Time, date and week
g) Temperature in °C / °F
h) Indoor temperature (0 °C ~ 50 °C)
i) Outdoor temperature (-44 °C ~ 70 °C)
j) Indoor and outdoor humidity (20 % - 95 %)
k) Outdoor/indoor temperature and humidity trend
l) Outdoor upper and lower temperature alert 
m) Max./Min. temperature and humidity memory
n) Low battery icon
o) Alarm and Snooze
p) LED back light
Buttons function
Power on
1. The LCD display fully for 2 seconds when power on, then with a sound BI into 3 
    minutes RF receiving.
2. Default time: 0:00 24H
3. Date: JAN/01 2018, MONDAY
4. AL: 7:00
5. Default temperature: °C
6. Weather station: partly sunny
TIME SETTING
1. In standard mode, hold      key to time setting. Setting item will twinkle by 1HZ.
2. Setting order is as follow:
    DCF:BEEP sound ON/OFF→RCC ON/OFF(Atomic ON/OFF)→Time ZONE→
    12/24HR→hour→minute→year→month→date→temperature unit→ exit
3. When setting, press ▲ once to go ahead at 1 step. Press and hold to go ahead 
    at 8 steps/second.
4. When setting, press ▼ once to go back at 1 step. Press and hold to go back at 8 
    steps/second.
5. Exit setting by press      or no any setting for 20S.
20. Calendar
21. Symbol Radio Control RCC
22. Tendency outdoor humidity
23. Outdoor comfortable level
24. MAX/MIN button
25. ALERT button
26. SNZ/LIGHT button
27. MODE button
28. UP button
29. DOWN button
30. Wall mount hole
31. External power supply socket
32. Battery Compartment 3xAAA 
33. Pedestal
34. Wireless signal indicator
      (Flashes when data is being sent to 
      the display unit)
35. Integrated hang hole
36. TX button
37. TX channel selector, select external 
      sensor channel
38. Compartment 2xAA batteries
Button
Mode
Standard mode
Press
 once
Hold
Press
 once
Hold
Press
 once
Hold
Time setting
Alarm setting
Check 
alarm
Go ahead 
at 1 step
----
Confirm 
setting
----
Go ahead at 
8 steps/second
Go ahead at 
8 steps/second
Switch channel
---
Clear memory
----
----
----
----
----
Max.&Min 
values display
----
----
Time setting
RF receiving
ON or OFF RCC
Confirm 
setting
Go ahead 
at 1 step
Go back at 
1 step
Go back at 
1 step
Go back at 
8 steps/second
Go back at 
8 steps/second
Check 
alert
---
---
---
ALERT setting
---
Active 
back-light (5S)
Backlight 
for 5s
Backlight 
for 5s
Alarm setting
1. Press      to alarm mode, hold      to set alarm. 
2. Set order is:hour→minute→exit
3. In set, press ▲ to go ahead by once. Hold ▲ to go ahead at 8 steps/second.
4. In set, press ▼ to back by once. Hold ▼ to go back at 8 steps/second. 
5. Press      or no handling in 20s will exit after set finish.
6. When check alarm, press ▲ or ▼ to open or close alarm. No handling in 5s will 
    go back to time display. 
Alarm sound
1. Alarm time:2 mintues
2. Alarm mode:
0-10s:one BI/second
10-20s:twice BIs /second
20-30s:four BIs /second
After 30s: continuous beep
3. When alarm, press        to snooze function.
4. Snooze function is 5 minutes.
4. No matter alarm or snooze, press any button to stop alarm except 
Indoor temperature and humidity
1. Indoor temperature 0°C ~ 50°C, display LL.L when below 0°C and display HH.H 
    when higher than 50°C.
2. Humidity range: 20%-95%, display 20% when below 20% and display 95% when 
    higher than 95%
3.When alarm ringing or RF receiving, temperature and humidity test will be stopped.
RF receiving function
The clock will register RF signal for 3 minutes automatically when power on then 
enter RCC receiving.
• In RF registration process, Antenna symbol increase:
• When register RF successfully, it will display maximum signal  
• During synchronous progress, if receive fails once, then the signal  
• If RF synchronization failure to reach in one hour, data will display --- ,--°C, --% 
   and ID reserved, then automatically open long receiving mode for 3 minutes. If 
   still fail, clock will start for 3 minutes receiving in next hour.
RCC receiving function
• The clock starts to RCC receiving after RF receiving.
• Hold ▲ to RCC receiving.
• It will automatically receive RCC everyday.
• If receiving RCC, the symbol of antenna tower flash in      ; if receiving success, 
  the symbol of antenna tower change from    →     .
• The symbol display in       when with DST.
• When receiving RCC, hold ▼ to exit RCC receiving. Except        button with light 
  on function, rest keys are without function .
 INSTRUCTION MANUAL