Polysense Technologies Co. Ltd. WXS8000 用户手册

下载
页码 36
 
 
User Guide 
Revision 0.1 
 
 
XXX-XXXX 
Polysense WxS8000 User Guide 
Rev 2.3, Mar 26, 2018 
 
Polysense, Inc. Confidential 
Page 9 
 
 
Sensor type 0 
0 (Battery Voltage) 
Presence 0 
1 (the sensor is present on the board) 
Administration state 0 
1 (the sensor is enabled) 
Scheduling cycle 0 
120 (so the sensor scheduling cycle is 30 * 120 = 3600 seconds) 
Sample number 0 
1 (sample sensor data only for once in each scheduling cycle) 
Sample cycle 0 
N/A 
<Sensor type n> 
Sensor type n specific configuration if applicable 
Table 3.1-1 WxS8000 PPB default settings 
NOTE: 
1.  If the sample number is set to >= 2, then it will enable the dense data sample for this sensor 
type (i.e. the sensor type will be sampled for multiple times as specified by the sample number 
in one scheduling cycle) 
2.  Only Vibration sensor types are supported with dense data sample at this point, including 
Vibration with 3-axis and Vibration with 2-axis 
3.  It only supports to do the dense data sample for one sensor type at one time, if Vibration with 
3-axis and Vibration with 2-axis are both enabled with the dense data sample (both are set as 
sample number >=2), then only the Vibration with 2-axis sensor type will be enabled actually