  EVC200 Quick Start Guide 
Specifications 
 
 
The EVC200 Z-Wave Valve Controller requires 12V DC input at 1Amp (AC to DC Adapter included). The EVC200 can be included with, and 
controlled using any Z-Wave compatible controller. The EVC200 also acts as signal repeater for the Z-Wave network, extending the Z-Wave 
transmission as part of the “mesh network”.  The EVC200 is designed to work with a pre-installed standard levered ball type water shut off 
valve.   If your water shut off valve is not a levered type, consult a plumber to have your shut off valve changed to a levered type.   
 
 
The EVC200 is designed to be installed onto an existing levered type ball valve as detailed below. Caution: If you do not have experience 
installing and configuring EVC200 type of devices, please consult a professional installer. 
 
 
 
 
Model: EVC200 (U.S.) 
 
Rated Voltage: 12V DC/1A 
 
Z-Wave Plus
  
 
Wireless Range: 30M (line of sight) 
 
Valve Pressure:1.6Mpa 
 
Valve Size: ½” , ¾”, 1” (optional 1.25”) 
 
Close Time: 5 ~ 10 seconds 
 
Open Time:  5 ~ 10 seconds 
 
Torque: 30~60 kg.cm 
 
Accessories: 12V/1A power adaptor 
 
 
Including the EVC200 Z-Wave Automatic Valve with a Z-Wave Controller 
 
Including or Adding the EVC200 to a Z-Wave Controller:  Place the Z-Wave controller in includeing (learning) mode. Press the Power button 3 
or more times rapidly (within 0.5 seconds). Once the controller has acknowledged the inclusion, the EVC200 has been included in the Z-Wave 
network with the controller. Exit the including mode and you should see the EVC200 Automatic Valve under your list of devices.  Some devices 
(like the Vera controller) require that you reload or refresh the controller so it polls, identifies, and configures the new device. Once the 
configuration is complete, you can control the powered valve through your Z-Wave controller’s user interface.  The valve supports Open or On 
command and Closed or Off command through a standard Z-Wave controller.  The valve can also be open or closed with a single push of the 
power button on the unit, toggling from open to closed or closed to open.  The valve can also be open/closed manually by hand by pulling the 
clutch pin. 
 
Excluding or Removing the EVC200 from a Z-Wave Controller: Place your Z-Wave controller in exclusion (un-learning) mode. Once the 
controller is in exclusion mode, bring the EVC200 close to the Z-Wave controller (several feet) and press the Power button 3 or more times 
rapidly (within 0.5 seconds). Once the controller has acknowledged the exclusion, the EVC200 has been cleared of any previous inclusions. (It 
is recommended to keep the EVC200 within 1M/3ft of the controller when including or removing) 
 
There can be a number of reasons that the EVC200 does not work with your controller.  If the inclusion process does not work the first time, 
repeat the process but try “excluding” first and then complete the “inclusion” process.   
 
Mechanical Installation: 
Consult a plumber or professional installer for assistance with the mechanical installation. 
 
 
,908.4MHz,908.42MHz,916MHz