Wisesec Ltd. B0213A 用户手册
MOUNTING THE SENSOR
1) Choose the position according to plan the location of the sensors.
2) Stretch the wires from the power supply into the hole for the wires.
3) Mount the sensor base on the surface with screws.
4) Connect the sensor wires to the wires from the power supply: Red ‐ "+" Black ‐ "‐".
5) Mount the sensor on the base.
2) Stretch the wires from the power supply into the hole for the wires.
3) Mount the sensor base on the surface with screws.
4) Connect the sensor wires to the wires from the power supply: Red ‐ "+" Black ‐ "‐".
5) Mount the sensor on the base.
WIRE SIZE REQUIREMENTS
Use #26 AWG or wires with a larger diameter. Use the following table to determine required
wire gauge (diameter) and length of wire between the sensor and power supply.
wire gauge (diameter) and length of wire between the sensor and power supply.
Wire Length
<35m
<60m
<100m
<150m
Wire Gauge
26AWG 24AWG 22AWG
20AWG
WIRE CONNECTIONS
Run the cable through the cable entry hole and connect the wires in accordance with the
following instructions:
following instructions:
Red wire – (+5VDC) ‐ Connect to a positive Voltage output of 5VDC source (power supply)
Black wire – (GND) – Connect to ground output of 5VDC source (power supply)
IMPORTANT:
1) Product shall be powered from certified
Limited Power Source adapter.
2) Do not install the sensor where it may
encounter water, steam or oil.
3) Do not aim the sensor directly at sources
of rapid heating or cooling such as : forced
air ducts, heaters.
air ducts, heaters.