CartaSense Ltd. LANUSG01 用户手册

下载
页码 64
 
Appendices
 
 
 Installation, Operation & Maintenance of the Wireless Sensing Family 
31 
 
A.2:  
Resident Sensor Specifications 
Networking and system Configuration 
Communications Network  
Multi-hop, cluster tree wireless sensor network 
Number of Communications 
Channels: 
Up to four 
Multi-hops (Store and Forward) 
Up to 15 hops 
Network Robustness 
Self-healing, adaptive 
Temperature measurement Rate 
per RS 
Remotely programmable from 2 min up to 255 
min  (default 10 min) 
Certifications & Compliances 
FCC,CE, WHO, RoHS, EN 12830, EN/UL 60950 
UHF Network 
Operating Frequency 
433 MHz ISM band.  
Maximum rated output power 
 
Less than 0 dBm; Matching into 50 Ω 
Impedance.  
Effective radiated power 
Less than 0 dBm 
RF Read Range 
Up to 500 m per hop in free space 
PHYSICAL AND ENVIRONMENTAL  
Dimensions:  
100 mm x 63 mm x 22 mm 
Weight:  
70 g 
Color:  
Grey 
Power 
DC power input 
2 AAA batteries (not included) 
Measurement specifications 
 
Maximum measurement Range 
Temperature: -35ºC to +65ºC 
Relative Humidity: 35% to 100%  
(from 0ºC to +60ºC) 
Accumulated Operation Time 
Over 400 days if connected to the WL network 
at 0ºC  
Temperature Measurement 
Accuracy 
±0.5ºC (in the range of -10ºC to +50 ºC)  
±0.8ºC (in the range of -35ºC to -10ºC & 50ºC 
to +60ºC) 
Temperature Resolution 
0.1 ºC 
Relative Humidity measurement 
accuracy 
±5% 
Relative Humidity Resolution 
1% 
Memory Capacity 
2700 measurement points of each temperature 
and relative humidity 
Storage Conditions 
-20 ºC to +65ºC  
Maximum continues temperature 
operation range  
-20ºC to +60ºC 
Special AAA batteries are required for below -20 
Celsius operation