CartaSense Ltd. LANUSG01 用户手册

下载
页码 64
 
Appendices
 
 
 Installation, Operation & Maintenance of the Wireless Sensing Family 
37 
 
A.6:  
M-Sensor (A-Sensor Sun) specification 
Networking and system Configuration  
Communications Network (between 
USG and RS & US):  
Multi-hop, cluster tree wireless sensor 
network  
Number of Communications Channels:   Up to four  
Multi-hops (Store and Forward)  
Up to 15 hops  
Network Robustness  
Self-healing, adaptive  
Temperature measurement Rate per 
RS  
Remotely programmable from 2 min up 
to 255 min (default 10 min)  
Certifications & Compliances 
FCC,CE, WHO, RoHS, EN 12830, EN/UL 
60950  
UHF Network  
Operating Frequency  
433 MHz ISM band.  
Maximum rated output power  
Less than 0 dBm  
RF Read Range  
Up to 500 m per hop in free space  
PHYSICAL AND ENVIRONMENTAL  
Water-proof  
IP67  
Dimensions:  
8.5 x 5 x h21 cm (Without the mount)  
9 x 7 x h21.5 cm (Including mount)  
Weight:  
250gr. (Without the mount, including 
batteries)  
300gr. (Including mount)  
Color:  
Grey  
Power  
DC power input  
2 replaceable AA batteries (not included)  
Measurement specifications  
Accumulated Operation Time  
Up to 3 years if connected  
Photosynthetic Photon Flux (PPF) 
Range  
–0 - 2000 μmol m
-2
 s
-1
  
 
Memory Capacity  
2500 measurement points of each 
temperature and relative humidity  
Remote configuration  
Product can be configured / programmed  
Storage conditions (without batteries)   -20ºC to +70 ºC  
Operating Range (Lithium batteries)  
Temperature: -30ºC to +60ºC  
operation range (Alkaline batteries)  
-20ºC to +50ºC (higher temperature 
available from several battery vendors)