Instruction Manual Of KUL01TX-01 
 
1.  Installation: 
1)Open the battery cover of KUL01TX-01,and put 2x AAA batteries into; 
2) There are 8 channels on the dial part of KUL01TX-01, which are 
“1” “2” “5” “15” “30” 
“NO CDS” “TEST1” “TEST2”. “TEST1” and “TEST2”are used by factory workers 
on  testing,  do  not  select;  If  need  work  at  night,  select  one  of  "1,  2,  5,  15, 
30
“according to your need of Time-delay. The time delay is a period of time from 
the  person  walk  into  and  out  the  detective  range  of  KUL01TX-01;  "NO  CDS"  is 
working in whole day and turned off by Time-delay 5 minutes; 
3)    According to the detective range, install the plastic mounting of KUL01TX-01 to 
the right position on the wall; Adjust the angle of sensor window, which face to the 
needed area you want. 
2.    Function: 
        1) KUL01TX-01 will not work during the day when select 
“1,2,5,15,30”.    At 
night, when person go across the detective range of KUL01TX-01, it will send 
an “ON” signal to KUQ01RF-01 and off power when “Delay Time” was gone. 
        2) 
Select “NO CDS” which will work in whole day. When person goes across the 
detective  range  of  KUL01TX-01,  it  will  sen
d  an  “ON”  signal  to  KUQ01RF-01 
and  turn  off  after  5  minutes  when  it  enters  into 
“Time  Delay”  mode 
automatically.   
                3) Under selection of 
“1,2,5,15,30”, the LED inside of KUL01TX-01 will be 
turned ON for 10 seconds when it’s from the day enters into the night. 
                4)  The  LED  inside  of  KUL01TX-01  will  be  flicker  once  time  when  change  the 
channel to the next one.     
3. Specification: 
        Voltages: 2* AAA batteries 
              Remote Distance: 8M 
              Frequency: 315MHZ 
              Battery Life: 1 year