LOG-PT1000(-30)  Wireless Temperature Data Logger
Handling
The  logger  consists  of  the  electronics  (housing:  POM  plastic,  20x160  mm)  and  the  Sensor
(Standards: 0 cm (LOG-PT1000) and 30 cm  (LOG-PT1000-30)
If  the  enclosure  must  be  opened  (e.g.  for  battery  replacement),  please  check  the  o-ring
(sealing) very carefully! Use lubricant (to protect the o-ring) before reassembling.
We recommend to lubricate the enclosure additionally after reassembling and before using in
the  field  (e.g.  by  Spray  Vaseline).  Please  ensure,  that  no  force  affects  the  connector
sensor<->logger in the field. 
If  required  (as  additional  protection  against  smut),  we
recommend to use a small piece of fabric (like cotton) to
cover the enclosure before putting under the soil. Do not
cover the enclosure with plastic material, because of the
risk of accumulating liquid water!
About  the  range:  Optimal  range  (line  of  sight  in  open
environment) could be up to 300 meters for loggers with
separate antennas. If the sensor cable (like here) is used as antenna, a range of 100 meters is
realistic.  In  this  case  the  first  20  cm  of  the  sensor  cable  are  mostly  important  for  the
transmission. Hence in the picture on the right (a logger under soil) the cable is routed as a
loop.  Normally  depths  of 20-30  cm  still  allow  a  range of  10-30  meters.  On  request,  special
beam antennas with very high gain are available from us.
Please note: The devices are available with several different radio frequencies, depending on
the local regulations of the country (e.g.: 433 MHz in Europe, parts of Africa and Asia, 905
MHz in USA and Canada, ...). It is in the responsibility of the user, not to use devices that are
not allowed in the country of usage.
Technical Shortform  LOG-PT1000(-30)  Wireless Temperature Data Logger
15.07.2013
Soil
Fabric (optional)