14.2.2
  Select Tag – Loop Mode Example (Binary) 
The following request initiates Loop Mode with Auto-detect selected as the tag type: 
 
 
Length 
Flag 
Command 
Tag Type 
CRC 
Request 
<STX> 
0x05 
0x21 
0x14 
0x00 
0xC541 
 
 
 
Length 
Response 
CRC 
Response 
<STX> 
0x03 
0x1C 
0xF085 
The response 1C is immediately sent to indicate that the reader has successfully entered loop mode. 
The following responses will be received when an ISO-15693 tag is introduced into the reader’s field.  The responses 
below show the tag being read three times: 
 
 
Length 
Response 
Tag Type 
Data (TID) 
CRC 
Response 
<STX> 
0x0C 
0x14 
0x01 
E0 04 01 00 08 AE D8 BD 
0xBBF3 
Response 
<STX> 
0x0C 
0x14 
0x01 
E0 04 01 00 08 AE D8 BD 
0xBBF3 
Response 
<STX> 
0x0C 
0x14 
0x01 
E0 04 01 00 08 AE D8 BD 
0xBBF3