Important information
Target group
These installation instructions are intended for Techem trained 
personnel. We do not mention any elementary job steps.
Intended use
The  Mod5  meter  transmitter  is  used  for  upgrading  the 
Techem S-30D-Vario 3 water meters to radio. 
Safety and hazard information
As supplied, the Mod5 meter transmitter has an integral battery 
whose capacity is enough for the intended period of use. – It is 
not  necessary  to  change  the  battery  and  it  is  
also  not 
permitted.
Delivery, transport and storage
Scope of delivery
The standard delivery of the product contains:
• the installation instructions with conformity
declaration,
• one (1) Mod5 meter transmitter
Transport
The  Mod5  meter  transmitter  must  not  be  subjected  to  blows, 
shocks,  shaking  or  vibration.  Transport  should  therefore  be  in 
the  original  packaging  if  possible,  or  in  another  suitable 
packaging.
Storage
The following storage conditions must be adhered to
without exception: max. temperature: + 50 °C / min.
temperature: - 20 °C.
Techem Water Services Inc.
5661 Airport Blvd.
Boulder, CO 80301
www.techem.com
Mod5 meter transmitter
Mod5 meter transmitter (Art. No. xxxxxxxxxx)
ASSEMBLY INSTRUCTIONS
Sealing ring
Mod5 meter transmitter
S-30D-Vario3 meter
Installation
Retooling of S-30D-Vario3 meter to radio
1 If  present:  break  open  the  ring  seal  on  the  meter
casing and detach  it.  To  do  this, pass  a  screwdriver  blade 
into  one  of  the  openings  of  the  ring  seal  and  twist  to  one 
side.
2 Remove the front cap from the meter casing.
The  area  of  the  meter  casing  where  the  Mod5  meter  transmitter 
makes  contact  must  be  clean  and  dry  – especially  in  the  area  of 
the ring seal. If necessary, clean this area with water and dry it. If 
this is still not enough, the meter casing must be changed.
3  Apply the Mod5 meter transmitter to the meter and 
allow it to click into place.
4  Lock the connection of the Mod5 meter transmitter to 
the meter casing using a ring seal.
5  Finish the retooling with optical head and PDA.
NOTE
Changes  or  modifications  made  to  this  equipment  not 
expressly  approved  by  Techem  Water  Services  may  void 
the FCC authorization to operate this equipment.
NOTE: This  equipment  has  been  tested  and  found  to 
comply with the limits for a Class B digital device, pursuant 
to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to 
provide  reasonable  protection  against  harmful  interference 
in a residential installation. This equipment generates, uses 
and can radiate radio frequency energy and, if not installed 
and  used  in  accordance  with  the  instructions,  may  cause 
harmful  interference  to  radio  communications.  However, 
there  is  no  guarantee  that  interference  will  not  occur  in  a 
particular installation. If this equipment is assumed to cause 
harmful interference to radio or television reception, consult 
the local Techem representative.