 Box Content  
1 x PIR Motion Detector
1 x Bracket
1 x User Manual
1. Detection window
2. LED indicator
3. Bracket
Before Using for the First Time   
Open the case and remove the battery activation strip to activate the 
batteries. Self-testing starts for 30 seconds.
www.etiger.com
ES-D1A
Wireless Motion Detector
Installation   
Fix the bracket on the wall with screws and attach the detector to the 
bracket. Adjust the bracket to change the detection distance and angle. 
It is recommended to mount the detector 2m from the ground.
Avoid mounting the detector close to windows, air conditioner, heater, 
refrigerator, oven, sunshine and places where the temperature changes fast 
or where the air stream flows frequently.
If two detectors are installed in the same detection scope, adjust the 
location to avoid interferences and false alarms.
The detector is more sensitive to cross movements than vertical movements.
Top view
Side view
Detection scope
PCB Layout  
Jumpers for Zone setup
Tamper switch
Infrared sensor
AA 1.5V LR6
Antenna
LED working indicator
Infrared sensor: Detects the infrared rays released by human body 
motion. Do not touch the surface. Keep the surface clean.
Tamper switch: When the alarm system is armed, the tamper switch 
will trigger the alarm if the case is opened.
Jumpers for Zone setup: The jumpers enable you to assign the 
detector to a specific zone. Refer to the user manual of your alarm 
system for more information on zone set up.
Mode Setting   
Testing mode
Once the self-testing is complete, long press the test button. The sensor 
switches to testing mode, and scans once every 10 seconds. After 3 
minutes, the LED blinks twice, and the sensor switches to working 
mode. 
Working mode / Stand-by mode
In working mode, if the sensor is triggered more than twice within 3 
minutes, it will switch to standby mode to save power. If no movement 
is detected within the next 3 minutes, the sensor goes back to working 
mode.
Register the detector in the alarm system
Switch to Connection Mode on the control 
panel. Press the test button of the sensor 
twice. The control panel beeps once: the 
motion detector is registered. If you hear 
two beeps, the detector has already been 
connected.
To check if the registration is complete, arm 
the system and trigger the sensor again. 
If the siren rings out, the registration is 
successful.
Test 
Button
Specifications   
Power Supply:
DC 3V (AA 1.5V LR6 x2)
Static current:
≤90uA
Transmitting current:
≤9.5mA
Transmission distance:
≤ 80 m (in open area)
Radio-frequency:
  315MHz (±75KHz)
Housing material:
ABS plastic
Operating conditions:
Temperature: -10°C ~ +55°C
Relative Humidity: ≤80% (non-con-
densing)
Detector dimensions:
107 x 53 x 32 mm
Bracket dimensions:
52 x 30 x 26.5 mm
LED indications   
Blinks continuously: Self-testing 
Blinks once: An intruder is detected
Blinks twice: Self-testing is complete; entering working mode.
Blinks 3 times every 3 seconds: Under-voltage indication: the batteries 
must be replaced (the user will be informed by SMS when the batteries 
are low if the detector is registered in the control panel).
Standards   
This product bears the selective sorting symbol for waste electrical 
and electronic equipment (WEEE). This means that this product must 
be handled pursuant to European Directive 2002/96/EC in order to be 
recycled or dismantled to minimize its impact on the environment.  For 
further information, please contact your local or regional authorities. 
Electronic products not included in the selective sorting process are 
potentially dangerous for the environment and human health due to 
the presence of hazardous substances.
In compliance with European laws.
This product was designed and manufactured in compliance with 
Directive 2002/95/EC of the European Parliament and of the Council on 
the restriction of use of certain hazardous substances in electrical and 
electronic equipment (RoHS Directive - RoHS) and is deemed to comply 
with the maximum concentration values set by the European Technical 
Adaptation Committee (TAC).
Manufactured in China.
Images, illustrations and text are non-contractual. ETIGER and the ETIGER logo are 
registered trademarks and the property of ETIGER.
Copyright © 2014 ETIGER. All rights reserved.
ETIGER EUROPE
Rue de la Loi, 25, 7100 La Louvière, Belgique
service@etiger.com
ES
-D1A
-UM
-EN20140724-1.1-
W
This user manual is available in other languages at
www.etiger.com/eu/support