DB ELETTRONICA TELECOMUNICAZIONI S.P.A. MOZART500 用户手册

下载
页码 87
 
 
26 /87
5.2.4
 
AUXILIARY CHANNELS LEVEL 
 
Pressing  the  DOWN  button  you  can  see  the  MPX  External  and  RDS  External  levels  indicated  in 
dBu. 
 
Fig. 5.7 – Auxiliary channels 1 input levels 
 
Pressing the DOWN button you can see the SCA and AUX levels indicated in dBu. 
 
 
Fig. 5.8 – Auxiliary channels 2 input levels 
 
 
5.2.5
 
VOLTAGES AND CURRENT 
 
This page allows the visualization of the unit analogic working values:  
VPA = voltage that supplies the RF module in Volt.  
IPA = current absorbed by the RF module in Ampere. 
VPu = Main power supply voltage in Volt. 
VT = Voltage Tuning (VCO working voltage) in Volt.  
 
 
Fig. 5.9 – Voltages and Current page