Vital Home Systems LLC VC100 用户手册

下载
页码 17
P a g e
 | 
 
 
© 2015 Vital Home Systems 
as it is in the OPEN position and needs to remain that way for the rest of installation.  Depress the Red 
button on the bottom for 3 seconds. 
STEP 2. Check Ball Valve Alignment BEFORE installation- If the ball valve is attached to the VC100, look 
into the open end of the ball valve to verify it is open.  If the ball valve is not attached to the VC100 skip 
to STEP 3 then perform STEP 5 and attach the valve then verify alignment using this step.  With the valve 
attached, when manually commanded, the ball valve should open to full port and closes with no light 
coming through then proceed to STEP 3.  ONLY If the ball valve does not appear to open to full port or 
close fully, contact Vital Home Systems. Ensure the VC100’s last position is in the OPEN position before 
proceeding to STEP 3. 
CAUTION!  NEVER  PUT ANYTHING  INTO  THE  BALL  VALVE  ESPECIALLY A  BODY  PART. THE  MOTOR  IS 
STRONG ENOUGH TO SEVERELY DAMAGE OR SEVERE A FINGER! 
STEP 3. Remove lower Valve Coupler Mount- Ensure the VC100 and the valve (if installed) is in the 
OPEN position before removing Valve Coupler Mount.  DO NOT change the motor position or valve 
position.
  If you accidently changed the valve position.  Toggle the Manual Valve Control Switch to the 
left which is the OPEN position.  The motor will not operate if you toggle the switch left and it is in the 
open position.   
If the valve was installed when you received your VC100, remove the four large bolts from the Valve 
Coupler Mount with the large supplied allen key.   This will expose the valve stem coupler.  Using the 
small allen key and a small metric wrench, loosen the four bolts holding the valve to the coupler mount 
and separate the valve from the mount. 
Step 4. Install Valve on Water Line- Provide the VC100 supplied valve to a licensed and experienced 
plumber  for  installation  onto  the  water  line.    Typically  the  valves  are  installed  on  the 
house/condo/apartment water main after the water meter, then after the main water shut off and after 
the water regulator.  Please consult with your plumber for the best location for the VC100 valve while 
still providing access for battery replacement and manual operation.   Do not place the VC100 or run 
plumbing outside of a temperature controlled structure in climates where the temperature can cause 
water to freeze. The VC100 can be installed horizontally, or sideways position.  The valve may be installed 
vertically but with the valve at the bottom of the VC100 and the switches at the top.  If the VC100 is 
installed vertically with the valve at the top, this WILL CAUSE DAMAGE to the batteries.  Do not install 
the VC100 upside down.
  Select a location where you have enough room to mount and service the 
VC100 Motor. Ensure the VC100 valve is in the OPEN position when installed.
 
CAUTION! STOP AND READ THIS! IF YOUR HOME HAS A WATER FIRE 
SPRINKLER  SYSTEM  OR  WATER  FIRE  SUPPRESSION  SYSTEM, 
IT  IS 
IMPORTANT  THAT  THE  VC100  IS  NOT  INSTALLED  BEFORE  OR  ON  A  FIRE  SPRINKLER  OR  FIRE 
SUPPRESSION WATER LINE.  INSTALLATION BEFORE OR ON A FIRE SPRINKLER OR SUPPRESSION WATER 
LINE MAY CAUSE THAT SYSTEM TO FAIL!