Wall Mounted Reader Installation 
This installation guide applies to the following types of readers: 
• 
ET10 – Mullion Reader 
Included: 
• 
(2) #6 Screws 
• 
Reader, Backplate, and Wall Plate 
• 
(1) #4-40, (1) pin-in-torx
 
 
   
The Following tools will be needed to install  
a wall mount reader: 
• 
Phillips Screwdriver 
• 
6-32 Tap (if installing on metal) 
• 
1” (25mm), 1/8” drill bits 
• 
T8 Security Torx Bit (optional for increased tamper 
detection) 
Common Cable Connections 
Red 
Power In 
Black 
Ground 
Shield 
Shield Ground 
Brown* 
Tamper Out 
Green 
Wiegand Data 0 / 
RS 485A 
White 
Wiegand Data 1 / 
RS 485B 
Yellow* 
Beeper Control 
Blue* 
Green LED Control 
Orange*  Red LED Control 
Max Length to Panel 
Length 
AWG 
200’ (60 m) 
22 
300’ 
20 
500’ 
18 
Current @ 12 V and 25 C 
Avg. mA 
Max. mA 
100 
160 
Wire the Cable to the Control Panel 
 
        Attach the Reader to the  
        Wall plate  
Align the reader so that the tabs of the base plate 
slide into the slots on the wall plate and slide the 
reader into position.  
 
*these wires are only used in 
Wiegand readers.   
Mounting Holes for Wall Plate 
Drill two mounting holes at a minimum of 1.7” apart. 
Drill a ½” hole in the center for the pigtail wire to pass 
through. Use the wall plate as a guide for drilling.  
Install Metal Wall Plate 
Once the holes are prepared, screw the wall plate in 
using the provided #6 screws.  
 
½” Hole for 
Pigtail 
Mounting hole 
distance is 
adjustable, use 
the provided 
#6 screws