Nauticast GmbH NAUTICASTA2 用户手册

下载
页码 80
 
 
Page 28 of 80 
1001001-2EN A2 Product Manual 2_0 
 
 
4.4.13  Main Menu  Config  Interface  Language 
Parameter Name 
Description 
Language 
Changes  the  language  in  all  the  menus  and  views  of  the 
NAUTICAST  A2.  The  changes  will  take  effect  immediately 
when pressing “Save”. 
 
4.4.14  Main Menu  Config Interface  Port Rate 
Parameter Name 
Description 
Baud Rate 
Changes the baud rate (bits per second) for the corresponding 
serial port. 
Checksum 
When set to “Required”, all messages that are input on  the 
corresponding serial port to the NAUTICAST A2 must have a 
valid checksum. 
When  set  to  “Disabled”,  messages  both  with  and  without 
checksum are accepted on the corresponding serial port. 
 
4.4.15  Main Menu  Config Interface  Miscellaneous 
Parameter Name 
Description 
SSD Password 
Changes the value of the  SSD password  level. When set to 
“None”,  no  password  is  required  when  configuring  the 
transponder with an SSD sentence from e.g. an ECDIS via the 
serial port interface. 
When set to “User”, an SPW sentence with the correct user 
level password must be sent before the SSD on the serial port 
interface. 
Ship Size Mode 
This affects how the user should input the ship size, convoy 
size and antenna positions. See section 4.4.4 for more details. 
AIS GPS Output Port 
Defines on which serial port the NAUTICAST A2 should output 
data from the internal GPS. When set to “None” no internal 
GPS data will be output. 
External Switch 
This parameter specifies if there is a blue sign switch or silent 
switch  connected  to  the  orange  and  brown  wires  of  the 
NAUTICAST A2 Power Cable. 
If no switch is used, set the parameter to “No Function”. 
See sections 3.6.7.1 and 3.6.7.2 for more information about 
the blue sign switch and silent switch. 
Require Text Msg ACK 
This  parameter  determines  if  an  ACK  msg  is  required  as  a 
response  when  sending  addressed  binary  text  messages  to 
another target. 
Automatic PoB Broadcast 
Enable  automatic  6  minute  periodic  broadcast  of  passenger 
information. See section 4.13 for details on message types. 
 
4.4.16  Main Menu  Config  System Settings 
Parameter Name 
Description 
System Mode 
Determines if the NAUTICAST A2 should operate as a Class A 
transponder  or  as  an  Inland  transponder.  This  parameter 
affects which config parameters and menus that are visible in 
the system. 
Range Unit 
This  parameter  determines  the  unit  for  the  range  value  of 
targets in the Target List, Extended Info view and Plot view. 
The  range  value  can  be  calculated  in  nautical  mile  (NM), 
kilometre (km) or statute mile (Sm). 
Speed Unit 
This  parameter  determines  the  unit  for  the  SOG  value  of 
targets in Extended Info view and Plot view. The SOG values 
can be calculated in knots (kn), kilometres per hour (km/h) or 
miles per hour (mph). 
Plot Compass 
This parameter determines how the plot of AIS targets should 
be oriented.