RuiXingHengFang Network Co. Ltd. APC350F 用户手册

下载
页码 16
V1.6 2016-11-16
www.risinghf.com
6
4.3 Mechanical Specifications and IPx
Mechanical size will be similar to 90x140x40 mm (TBD) or smaller.
The enclosure of the MIU should be IP6x. All the box mounting connectors and external connectors should be
IP6x.Irrigation methods sealing glue will be used to achieve excellent water and dust effects.
4.4 FCC compliant
MIU should be FCC compliant.
EMC would comply with FCC part 15 Class B.
Radio requirement should comply with FCC 15.247.
5 MIU Application Layer Design
The part presents the application layer protocol implemented in the MIU. The application layer leverages on the
LoRaWANspecifictions v1.0.1 released 2016. Figure 5 1 show the LoRaWANMIU flow chart in operation.
5.1 LoRaWAN Activation
After the MIU is activated and powered it will try to join an available LoRaWAN network in its vicinity. After
joining the LoRaWAN at the LoRa MAC level the MIU will send a status message to create a link with the sensors'
network NMS.