BL ident
No mounting of the data carrier directly on metal
The data carriers (with the exception of high temperature data 
carriers) may not be mounted directly on metal. Non-metallic 
spacers (see chapter 9, Accessories) enable mounting which does 
not lead to an interruption of the functions (Fig. 6).
The data carriers may not be mounted so that the necessary 
minimum distance to metal and to the data carriers around them is 
less than the minimum distance. The minimum distance is 
dependent on the housing design of the read-write head; a = 10 mm 
around the data carrier can be assumed (Fig. 7). The high 
temperature data carrier (see page 5 - 2, table 1) can be constructed 
so that it can be mounted directly on metal without the need for 
additional measures.
Figure 6
Installation with 
spacers
Figure 7
Installation 
considering the 
minimum distance 
from metal
h
metal
non-metallic spacer
data carrier
a