Werner Turck GmbH & Co. KG TNCK40 用户手册

下载
页码 202
2 – 5
BL ident System – Planning
D101583 0207
BL ident
2
Dwell time of the data carrier T
d
The dwell time T
d
 is the time in which the data carrier is present in 
the transfer zone of the read-write head as it passes by. The read-
write head exchanges data with the data carrier during this time.
The dwell time T
d
 is calculated as follows:
T
d
 = L
Sr
 / V
Tag
where:
L
Sr
:length of the transfer zone
 
V
Tag
:speed of the data carrier in dynamic operation
In static mode the dwell time can be as long as necessary. The dwell 
time must be long enough to ensure that communication with the 
data carrier has been completed.
In dynamic operation the dwell time is defined by the system 
environment. The dwell time must be matched to the data quantity 
to be transferred. Conversely, this means that the shorter the dwell 
time, the lower the quantity of data to be transferred.
Calculation of the maximum quantity of user data in dynamic operation
The calculation of the maximum user data quantity is dependent on 
the read-write head used and the corresponding data carrier.
Example: 
 
Read-write head: TB-M18-H1147,
 
Data carrier: TW-R30-K2
 
Pass speed: 0.5 m/s
Note
At www.turck.com various examples relating to this topic can be 
examined with the BL ident configurator.