Asrock X79 Extreme3 X79 EXTREME3 用户手册

产品代码
X79 EXTREME3
下载
页码 73
64
3.5  Hardware Health Event Monitoring Screen
In this section, it allows you to monitor the status of the hardware on your system, 
including the parameters of the CPU temperature, motherboard temperature, CPU 
fan speed, chassis fan speed, and the critical voltage.
CPU Fan 1 & 2 Setting
 
This allows you to set CPU fan 1 & 2’s speed. Confi guration options: [Full 
On] and [Automatic Mode]. The default value is [Full On]. 
Chassis Fan 1 Setting
 
This allows you to set chassis fan 1’s speed. Confi guration options: 
 
[Full On], [Automatic Mode] and [Manual]. The default value is [Full On]. 
Chassis Fan 2 Setting
 
This allows you to set chassis fan 2’s speed. Confi guration options: 
 
[Level 1] to [Level 4]. The default value is [Level 4]. 
Chassis Fan 3 Setting
 
This allows you to set chassis fan 3’s speed. Confi guration options: 
 
[Level 1] to [Level 4]. The default value is [Level 4]. 
SB Fan 1 Setting
 
This allows you to set SB fan 1’s speed. Confi guration options: [Full On] 
and [Automatic mode]. The default value is [Automatic mode].
 
Target SB Temperature
 
 
This allows you to set the target temperature to activate ASRock
 
 
X-FAN. The default value is [50
o
C/122
o
F].
 
Target Fan Speed
 
 
This allows you to set target fan’s speed. The default value is [Level  
 
1] (ASRock X-FAN deactivated).
Over Temperature Protection
 
Use this to enable or disable Over Temperature Protection. The default 
value is [Enabled].