iStarUSA TC-750PD1 用户手册
ϠϠ
LOAD REGULATION TEST TABLE
+5V +3.3V +12V
1
+12V
2
+12V
3
+12V
4
-12V +5Vsb
LOAD1
2.0A
0.5A
1.0A
1.0A
1.0A
1.0A
0.0A
0.0A
LOAD2
6.0A
4.0A
1.0A
1.0A
1.0A
1.0A
0.0A
0.5A
LOAD3
16.0A
30.0A
2.5A
2.5A
3.0A
3.0A
0.3A
1.0A
LOAD4
28.0A
13.0A
8.5A
9.0A
10.0A
10.0A
0.3A
1.0A
LOAD5
7.0A
6.0A
13.0A
13.0A
14.0A
14.0A
0.5A
1.5A
LOAD6
28.0A
0.5A
11.0A
12.0A
13.0A
13.0A
0.5A
2.0A
LOAD7
4.0A
3.0A
14.0A
14.0A
13.0A
13.0A
0.8A
2.5A
LOAD8
2.0A
30.0A
11.5A
13.0A
13.0A
14.0A
0.8A
3.0A
2.1 REMOTE ON/OFF
TTL High/PS-OFF; TTL Low/PS-ON
V
IL
=0.8Vmax, I
IL
=-1.6mAmax
@Vin=0.4V
V
IH
=2.0Vmin @Iin=-200uA, V
IH
=5.25Vmax @open ckt.
2.2 HOLD-UP TIME
16msec (minimum) at 80% of full load at 230Vac input.
2.3 POWER GOOD DELAY
100-500 msec.
2.4 POWER FAIL DELAY
>1 msec.
2.5 TURN-ON DELAY TIME
2000 msec max at Nominal Line Full Load.
2.6 TRANSIENT OVERSHOOT
+/- 10% max with 20% load change on all outputs are 50% of the
rated. Load slew rated 0.5A/uS and capacitive load as below: