LSA-PLUS
®
 Series 
avaNT
i Modules 
and 
Accessories
Features & Benefits
The 3-point Insulation Displacement Connection (IDC) method of termination gives durable and long 
lasting connections. 
1. Insulation clamping ribs hold wires firmly in position and isolate the contact area from vibration   
  and other forms of mechanical stress. 
2. Flexible silver-plated contacts*, positioned at 45
angle across the axis of the wire, make a solid,   
  gas tight connection. 
3. Constant axial and torsion restoring forces, created by the unique contract and plastic housing,    
  sustains a durable connection.  
 
Positioning the contacts at a 45
o
 angle leaves more wire between contact points and provides a 
reliable, stress resistant connection.  
Positioning contacts at a 90
angle produces a point of weakness subject to possible breakage. 
A correctly terminated IDC prevents:
• Corrosion 
• Loosening due to vibration 
• High resistance connections 
• Movement of the wire
If required, the connection can be redone easily and only the small portion of the wire must be 
removed. The connection can only be accomplished with the KRONE insertion tool, leading to 
greater contact security and assuring that when the connection is remade, no particles of insulation 
or wire remain in the connection area. Most importantly, the connection is repeatable. Every time 
a connection is made, the properties of the connection will be the same. The LSA-PLUS
®
 IDC is 
a reliable, secure and quick contact method. The method has been proven as an electrically and 
mechanically sound method of connecting normal voice and data cabling.
Contact at 90°
Contact at 45°
DISCONNECTION CONTACT 
S2 Disconnection Modules use a two piece contact (normally closed), with a convenient 
disconnection feature. By inserting a disconnect plug into a wire pair, you can temporarily or 
permanently disconnect the circuit. A Test Cord can be inserted into a pair to test each side 
(look both ways) of the circuit independently. This greatly accelerates fault identification.  
The centre contact point can also be used for monitoring or over voltage protection. 
 
 
CONNECTION CONTACT
Connection Modules have a one piece contact providing a continuous link between 
permanent wiring and jumper wiring, giving provision for monitoring access and 
overvoltage protection. 
 
SWITCHING CONTACT
Switching Modules house individual contacts and hence the circuits are disconnected when 
idle. By inserting plugs, cords or over voltage protection, the circuits can be connected when 
necessary.
DISCONNECTION CONTACT
CONNECTION CONTACT
SWITCHING CONTACT
DISCONNECTION CONTACT
CONNECTION CONTACT
SWITCHING CONTACT
DISCONNECTION CONTACT
CONNECTION CONTACT
SWITCHING CONTACT
* Modules with Tin Plated contacts are also available.