Accu-Tech 006K88-31130-D3 用户手册

下载
页码 4
SPECIFICATION SHEET LAN-1138-EN | PAGE 3
MIC
®
 DX Armored  
Plenum Cables, 6-24 Fibers
A LANscape
®
 
Solutions Product
transmission performance |
Optical Fiber   
62.5 
50 50 50 50 
Type (µm) Multimode 
Multimode Multimode Multimode Multimode
 
Single-mode*
ISO/IEC  
OM1 
OM2 
OM3
 
 OM4
 
 OM4
 
 OS2
11801 
Nomenclature
Fiber Code 
T T T T E
Performance  
30 
31 80 90 91 31
Option Code 
Wavelength
 
850/1300 
850/1300 850/1300 850/1300 850/1300 1310/1383/1550
(nm) 
 
    
 
Maximum  
3.4/1.0 
3.0/1.0 3.0/1.0 3.0/1.0 3.0/1.0 0.65/0.65/0.50
Attenuation
(dB/km) (dB/km)
Minimum  
200/500 
700/500 
1500/500 
3500/500 
3500/500 
– / – / –
Over Filled
Launch (OFL)
Bandwidth 
(MHz•km)
Minimum  
220/ – 
950/ – 
2000/ – 
4700/ – 
5350/ – 
– / – / –
Effective 
Modal
Bandwidth 
(EMB) 
(MHz•km)
Serial 1 
300/550 
750/600 
1000/600 
1100/600 
1100/600 
 5000 / – / –
 
Gigabit
Ethernet
Distance (m)
Serial 10 
33/ – 
150/ – 
300/ – 
550
/ – 
600
§
/ – 
10000/ – /40000
Gigabit
Ethernet
Distance (m) 
transmission performance |
*
 ITU 652.D compliant. 
 Meets 0.75 ns optical skew when used in all Corning Cable Systems Plug & Play
 Systems solutions. 
 Assumes 1.0 dB maximum total connector/splice loss. 
§
 Assumes 0.7 dB maximum total connector/splice loss. 
Notes:
1) Improved attenuation and bandwidth options available.
2) Bend-insensitive single-mode fibers available on request.
3) Contact a Corning Cable Systems Customer Service Representative for additional information.
4) 50 µm multimode fiber macrobend loss ≤ 0.2 dB at 850 nm for two turns around 7.5 mm radius mandrel.
|    PRETERMINATED SYSTEMS    
|    CABLES    |
    CONNECTORS    |  
  CABLE ASSEMBLIES    |    HARDWARE    |    SPLICE 
CLOSURES    |    TEST EQUIPMENT    |    SPLICE EQUIPMENT   