Traulsen RFF332NUT-HHS 用户手册

下载
页码 4
Project
Quantity
Item #
Model Specified:
CSI Section 11400
TRAULSEN
4401 BLUE MOUND RD.
FT. WORTH, TX 76106
PHONE 1 (800) 825-8220
FAX-MKTG. 1 (817) 624-4302
Website: www.traulsen.com
SECTION
7-4
NOTE: When ordering please specify: Voltage, Hinging, Door Size, Options and
any additional warranties. For fast order entry: Fax 1 (800) 765-8728.
Continued product development may necessitate specification changes without notice.
Part No. TR35806 (revised 1/07)
Specifications
Construction, Hardware and Insulation
Cabinet exterior front, one piece sides, louver assembly and doors are constructed
of 20 gauge stainless steel with #4 finish. Cabinet interior and door liners are
constructed of stainless steel. The exterior cabinet top, back and bottom are
constructed of heavy gauge aluminized steel. A set of four (4) adjustable 6"  high
stainless steel legs are included.
Doors are equipped with a gasket protecting metal door pan, removable plug
cylinder locks and guaranteed for life cam-lift, gravity action, self-closing metal, glide
hinges with stay open feature at 120 degrees. Hinges include a concealed switch to
automatically activate the interior incandescent lighting. Guaranteed for life, work
flow door handles are mounted horizontally over recess in door which limits
protrusion from door face into aisleways.  Doors have seamless, polished metal
corners.
Easily removable for cleaning, vinyl magnetic door gasket assures tight door seal.
Anti condensate heaters are located behind each door opening.
Both the cabinet and door(s) are insulated with an average of 2" thick high density,
non-CFC, foamed in place polyurethane.
Refrigeration System
A top mounted, self-contained, balanced refrigeration system using R-404A refriger-
ant is conveniently located behind the one-piece louver assembly.  It features large,
high humidity, interior mounted evaporator coils, coated with a plastic to retard corro-
sion, bottom mounted electric condensate evaporator, and an automatic preset time
activated electric defrost.  A cord and plug is supplied standard on one section mod-
els only.  Standard operating temperature is -20°F.
Controller
The easy to use water resistant  INTELA-TRAUL
®
 microprocessor control system is
supplied standard. Unit is NAFEM Data Protocol communication (NDP) ready.
Optional hardware required to be NDP compliant.  Third party software required for
network connection.  It includes a 3-Digit LED Display, Fahrenheit or Celsius
Temperature Scale Display Capability, Defrost Lockout Feature and an RS485 data
port.  In addition it includes audio/visual alarms for: Hi/Lo Cabinet Temperature, Door
Open, Clean Condenser, Evaporator Coil and Discharge Line Sensor Failures, and
Power Supply Interruption.
Interior
Standard interior arrangements include three (3) chrome plated wire shelves per
section, mounted on shelf pins. Shelves are full-width, and do not have any large
gaps between them requiring the use of "bridge" or "junior shelves."  Recommended
load limit per shelf should not exceed 225 lbs. Optional tray slides may be
purchased in combination with, or in lieu of these.  Both standard and optional
interior arrangements are completely installed at the factory.
Warranties
Both a one year parts and labor warranty and a five year compressor warranty (self-
contained models only) are provided standard.  An optional 2
nd
 year extended parts
and labor warranty is also available. In addition the INTELA-TRAUL
®
  control is
warranted by a two year parts and labor warranty.
FAST FREEZING NOTES:
For best results, it is recommended that loading be held to a minimum with more
frequent use of the freezing process made. Depending on the product variables of
type, size and placement, together with the desired quantity, the time necessary for
freezing will be determined.
Three factors: air temperature, air movement and refrigeration capacity, all
combine to provide fast freezing. A fourth factor is also important. This is the
combined effects of product type, size, quantity and placement. The smaller
the product size and quantity, the faster will its freezing be accomplished. The
placement of product with adequate spacing also assures faster freezing by allowing
freer movement of air around it.
Full load amps and plug style may vary depending on electrical options
chosen and condensing unit employed.
Equipped With One NEMA L14-20P Plug
(one section model only)
NOTES
NOTE: Figures in parentheses reflect metric equivalents.
1=Wattage is determined by listed amps X listed volts X an average run time of 70%
for refrigerators and 80% for freezers.
2=Based on a 90 degree F ambient and -20 degree F evaporator.
3=For approximate remote weights deduct 40 lbs. from respective net or gross weight.
For other information on remote models, please refer to spec sheet 12-2.
DIMENSIONAL DATA
RFF132WUT
RFF232WUT
RFF332NUT
Net capacity cu. ft.
24.2 (686 cu l)
51.6 (1462 cu l)
69.5 (1969 cu l)
Length - overall in.
29
7
8
 (75.9 cm)
58 (147.3 cm)
76
5
16 
(193.8 cm)
Depth - overall in.
35 (88.8 cm)
35 (88.8 cm)
35 (88.8 cm)
Depth - over body in.
32 (81.3 cm)
32 (81.3 cm)
32 (81.3 cm)
Depth - with door open
57
11
16
 (146.5 cm)
57
11
16
 (146.5 cm)
55
3
4
 (141.6 cm)
90 degrees in.
Clear door width in.
21
1
8
 (53.6 cm)
21
1
8
 (53.6 cm)
21
1
8
 (53.6 cm)
Clear half-door height in.
27
1
2
 (69.9 cm)
27
1
2
 (69.9 cm)
27
1
2
 (69.9 cm)
Clear full-door height in.
57
5
8
 (146.3 cm)
57
5
8
 (146.3 cm)
57
5
8
 (146.3 cm)
Height - overall on 6" legs
83
1
4
 (211.5 cm)
83
1
4
 (211.5 cm)
83
1
4
 (211.5 cm)
Shelf area sq. ft.
18.8 (1.75 sq m)
37.6 (3.49 sq m)
51.9 (4.82 sq m)
Net Wt. lbs.
415 (188 kg)
705 (320 kg)
870 (395 kg)
ELECTRICAL DATA
Voltage
208/115/60/1
208/115/60/1
208/115/60/1
Feed wires with Ground
4
4
4
Full load amperes
8.8
22.0
22.0
Wattage
1
1830
2928
2928
REFRIGERATION DATA
Refrigerant
R-404A
R-404A
R-404A
BTU/HR H.P.
2
4130 (1 HP)
2 x 8260 (1 HP)
2 x 8260 (1 HP)
REQUIRED CLEARANCES
In order to assure optimum performance, the condensing unit MUST have an adequate supply of
air for cooling purposes.  Therefore, the operating location must either have a minimum of 12”
clearance overhead of the condensing unit or allow for unrestricted air flow at the back of the unit.
Clearance of at least 12” above is required in order to perform certain maintenance tasks.