Nvidia 680I LT SLI 用户手册

下载
页码 80
 
 
 
Mainboard nForce 680i SLI/  
Mainboard nForce 680i LT SLI 
                                             
 
64
Rebuilding a RAID Mirrored Array 
 
This section will illustrate how to replace a failed drive with a new one, and rebuild the array 
to restore lost data on the newly installed drive. Rebuilding only applies to fault-tolerant 
arrays which are RAID 1, RAID 0+1, and RAID 5 arrays. 
 
 
 
 
1.  Before rebuilding an array, you must connect new hard disk(s) onto your computer.   
 
 
2.  Power on your computer. When the system boots up during the POST (Power-On Self 
Test), you will be given an opportunity to enter the NVIDIA RAID Setup Utility when the 
screen prompts you with the following message. 
 
“Press  F10  to enter RAID setup utility…” 
 
 
3. Press 
<F10> key to enter the NVIDIA RAID Setup Utility (note that you will only have a 
short window of time to press <F10> before the system continues the next step of the boot 
process). 
 
 
4.  Go to the screen shown as below. Press <Enter>