These designs comply with the current version of the American National 
Standard for Gas Water Heaters, Volume III, ANSI Z21.10.3 / CSA 4.3 as 
an  automatic  circulating  tank  water  heater,  and  automatic  storage  water 
heaters.
Detailed installation diagrams are found in this manual.  These diagrams will 
serve to provide the installer with a reference for the materials and methods 
of piping necessary.  It is highly essential that all water, gas piping and wiring 
be installed as shown on the diagrams.
Particular attention should be given to the installation of thermometers at the 
locations indicated on the diagrams as these are necessary for checking the 
proper functioning of the heater.
In  addition  to  these  instructions,  the  equipment  shall  be  installed  in  
accordance with those installation regulations in force in the local area 
where the installation is to be made. These shall be carefully followed 
in all cases. Authorities having jurisdiction should be consulted before 
installations are made.
In  the  absence  of  local  codes,  the  installation  must  comply  with  the 
current editions of the National Fuel Gas Code, ANSI Z223.1/NFPA 54 
and the National Electrical Code, NFPA 70. All documents are available 
from the Canadian Standards Association, 8501 East Pleasant Valley 
Road, Cleveland, OH 44131. NFPA documents are also available from 
the National Fire Protection Association, 1 Batterymarch Park, Quincy, 
MA 02269.
FOREWORD
RUF 100 199 ROUGH-IN-DIMENSIONS
Table 1.  RECOVERY CAPACITIES - NATURAL GAS / L.P.
 
    
    
 Approx.               
 
  Input 
 Gas 
 Gallon 
       TEMPERATURE RISE - DEGREES °F - GALLONS PER HOUR  
  Model  BTU/Hr.  Usage  Capacity 
30  40 
50  60  70  80  90  100  110  120  130  140
 RUF 199  199,900  nat/lp 
100 
767  575  460  384  329  288  256  230  209  192  177  164
 
   
    
 Approx.               
 
 
  Gas     Liter 
 
 
 TEMPERATURE RISE - DEGREES C - Liters PER HOUR     
  Model 
kW-Hr  Usage  Capacity  17  22 
28  33  39  44 
50 
56  61  67  72  78
  RUF 199 
58 
nat/lp 
379 
2904  2178  1743 1452 1245 1089  968  871  792  726  670  622
Recovery capacities are based on 95% thermal efficiency.
GAS VALVE PIPING
 
RUF - 199 
1/2" NPT