system diagnostics
your  water  heater  is  equipped  with  an  ignition  module  that 
incorporates a diagnostic system to assist in troubleshooting the 
appliance. The indicator codes on the ignition module are as follows:
table 11:
1 FLASh
System lockout (retries or cycles exceeded)
2 FLASheS
Pressure switch stuck close
3 FLASheS
Pressure switch stuck open
4 FLASheS
Open on high temperature limit switch (eco)
6 FLASheS
115 volt AC power reversed (check polarity)
7 FLASheS
Low flame sense signal (make sure flame sensor is in 
burner flame)
8 FLASheS
Check ignitor
continuous flash -> continuous flame sensed > 5 seconds without 
gas valve
continuous on -> internal control failure - replace ignition control 
module.
Use this diagnostic system in conjunction with the “OPerATIONAL 
CheCkLIST”  and  the  “SeQUeNCe  OF  OPerATION”  to 
troubleshoot the appliance. 
ignition module system
Before calling your service agent, the following checklist should 
be examined to eliminate obvious problems from those requiring 
replacement or servicing.
•  Check that “main manual gas shutoff valve” is fully open and 
that gas service has not been interrupted.
•  Check  that  after  following  the  appliance  OPerATING 
INSTrUCTIONS, the “Top knob” of the appliance gas valve 
is in “ON” position.
•  Check electrical supply to the appliance for possible blown 
(or  tripped)  fusing  or  power  interruption. Also  check  the  3 
amp fuse on the front of the digital thermostat (Fig. 2).
•  Is  the  water  temperature  in  tank  below  the  thermostat  dial 
setting on the appliance thermostat (calling for heat)?
•  It  is  possible  that  the  high  limit  (e.C.O.)  has  functioned  to 
shut off the appliance. See high Limit page 7 - high Limit 
Switch for reset procedure. Contact your service agent if limit 
continues to function to shut off appliance. 
for your information
serVice
The installer may be able to observe and correct certain problems 
which may arise when the unit is put into operation.  hOWeVer, 
it  is  recommended  that  only  qualified  service  agents,  using 
appropriate test equipment, be allowed to service the heater.
As  preliminary  step,  check  wiring  against  diagram,  check  for 
grounded, broken or loose wires.  Check all wire ends to be sure 
that they are making good contact.
electrical serVicing
LABeL ALL  WIreS  PrIOr  TO  DISCONNeCTION  WheN 
SerVICING    CONTrOLS.  WIrING  errOrS  CAN  CAUSe 
ImPrOPer AND DANGerOUS OPerATION.
VerIFy PrOPer OPerATION AFTer  SerVICING.
start up conditions
smoke/odor
It is not uncommon to experience a small amount of smoke and 
odor during the initial start-up. This is due to burning off of oil 
from metal parts, and will disappear in a short while.
strange sounds
Possible noises due to expansion and contraction of some metal 
parts during periods of heat-up and cool-down do not necessarily 
represent harmful or dangerous conditions.
Condensation causes sizzling and popping within the burner area 
during  heating  and  cooling  periods  and  should  be  considered 
normal. See “Condensation” in this manual.
condensation
Whenever  the  water  heater  is  filled  with  cold  water,  some 
condensate will form while the burner is on.  A water heater may 
appear  to  be  leaking  when  in  fact  the  water  is  condensation.  
This usually happens when:
a.  A new water heater is filled with cold water for the first time.
b.  Burning  gas  produces  water  vapor  in  water  heaters, 
particularly  high  efficiency  models  where  flue  temperatures 
are lower.
c.  Large amounts of hot water are used in a short time and the 
refill water in the tank is very cold.
moisture from the products of combustion condense on the cooler 
tank  surfaces  and  form  drops  of  water  which  may  fall  onto  the 
burner or other hot surfaces to produce a “sizzling” or “frying” noise.
operational conditions
smelly water
The  water  heater  has  at  least  one  anode  rod  for  corrosion 
protection  of  the  tank.  Certain  water  conditions  will  cause  a 
reaction  between  this  rod  and  the  water.  The  most  common 
complaint associated with the anode rod is one of a “rotten egg 
smell” in the hot water. The smell is a result of four factors which 
must all be present for the odor to develop:
a.   A concentration of sulfate in the supply water.
b.   Little or no dissolved oxygen in the water.
c.   A  sulfate  reducing  bacteria  which  has  accumulated 
within  the  water  heater  (this  harmless  bacteria  is 
nontoxic to humans).
d.   An excess of active hydrogen in the tank. This is caused 
by the corrosion protective action of the anode.
Smelly water may be eliminated or reduced in some water heater 
models by replacing the anode(s) with one of less active material, 
and then chlorinating the water heater tank and all water lines.