Intel® Server System SR1695GPRX TPS
Cooling Sub-System
Revision 1.5
31
Intel order number: G11332-006
The rotor fan connector pin-out definition is as follows:
Table 36. 8-pin Connector Pin-Out for Chassis Rotor Fan
Pin
Signal Name
Description
1 GND
Ground
2
12V
Power Supply +12 V
3
Tack0
Tach signal output
4
PMW0
PWM control signal input
4.3
Power Supply Fan
Each power supply module supports one non-redundant 40 mm fan. The fans control the
cooling of the power supply and some drive bays. These fans are not replaceable. Therefore, if
a power supply fan fails, you must replace the power supply module.
cooling of the power supply and some drive bays. These fans are not replaceable. Therefore, if
a power supply fan fails, you must replace the power supply module.
4.4
Air Duct Module
The chassis requires the use of an air duct module to direct airflow over critical areas within the
system. The following provides a summary and description of Air Duct Module.
system. The following provides a summary and description of Air Duct Module.
Figure 16. Air Duct Module