Intel SR1695GPRX1ACNA 用户手册

下载
页码 83
Intel® Server System SR1695GPRX TPS 
Cooling Sub-System 
Revision 1.5 
 
 
31 
Intel order number: G11332-006 
The rotor fan connector pin-out definition is as follows:  
Table 36. 8-pin Connector Pin-Out for Chassis Rotor Fan 
Pin 
Signal Name 
Description 
1 GND 
Ground 
12V 
Power Supply +12 V 
Tack0 
Tach signal output  
PMW0 
PWM control signal input 
 
4.3 
Power Supply Fan 
Each power supply module supports one non-redundant 40 mm fan. The fans control the 
cooling of the power supply and some drive bays. These fans are not replaceable. Therefore, if 
a power supply fan fails, you must replace the power supply module.
 
 
4.4 
Air Duct Module 
The chassis requires the use of an air duct module to direct airflow over critical areas within the 
system. The following provides a summary and description of Air Duct Module. 
 
 
Figure 16. Air Duct Module