IBM Flex System V7000 Expansion Enclosure 4939H29 用户手册

产品代码
4939H29
下载
页码 610
Chapter 11. SAN Connections and Configuration 
449
Draft Document for Review January 29, 2013 12:52 pm
8068ch11-SAN Config.fm
Figure 11-12   Internal and External port inclusion for FCoE VLAN
With this VLAN created, FCoE zones can be configured to map Compute Node 11 to IBM 
Flex System V7000 Storage Node via internal ports INTA3+4, and/or to external storage via 
port EXT12. The connectivity between Compute Node 11 and IBM Flex System V7000 
Storage Node is FCoE as shown in Figure 11-12 but any connection to external storage via 
port EXT12 is using fibre channel. The IBM Flex System Fabric CN4093 10Gb Converged 
Scalable Switch with this VLAN configured and using FCF provides an example of FCoE 
gateway for bridging FCoE and Fibre Channel networks. This is where Compute Node 11 
using FCoE connectivity can attach to external storage which is FC attached to the CN4093.
Administration Interface for CN4093
There are several methods of accessing CN4093 in order to configure, view or make 
changes:
1. Using a Telnet/SSH connection via the chassis management module
2. Using a Telnet/SSH connection over the network
3. Using the Browser-Based Interface (BBI) over the network
4. Using a serial connection via the serial port on the CN4093
The Telnet/SSH connection accesses two types of Command Line Interpreter (CLI), one is a 
text menu based CLI, the second is based on the international standard CLI (ISCLI). In this 
section we use the ISCLI to display and enter commands on the IBM Flex System Fabric 
CN4093 10Gb Converged Scalable Switch. For details on configuration and access for 
configuration see 
<< Author Comment - link to CN4093 install manual and CLI reference 
manual (not yet available)>>
Configuring for Fibre Channel Forwarding
In this section we will create the VLAN as shown in Figure 11-12 before creating zones and 
allowing access from Compute Node 11 to the IBM Flex System V7000 Storage Node located 
in the first 4 bays of the IBM Flex System Enterprise Chassis. A summary of the steps are:
1. Enable CEE and FIPS
2. Convert the omni-ports EXT11 and EXT12 (53,54) to Fibre Channel ports 
3. Create FCoE VLAN
4. Assign ports to FCoE VLAN
5. Enable FCF (must have at least one FC-Port to enable FCF)