Table 13-9   
Expansion canister Power LED states
2. If the power LED is on, consider the states of the status and fault LEDs for each expansion 
canister, as shown in Table 13-10.
Table 13-10   Expansion canister status LED states
LED 
layout
LED Name
Color
States
Power
Green
��
OFF – There is no power to the expansion canister. Make sure that the 
CMM has powered on the expansion canister. The CMM event log 
might indicate why the expansion canister has no power. Try reseating 
it. If the state persists, follow the hardware replacement procedures for 
the parts in the following order:
Expansion canister.
Expansion enclosure.
��
ON SOLID – The expansion canister is powered on. This is the normal 
state.
��
BLINK – The expansion canister is in a powered down state. Use the 
CMM to power on the expansion canister.
��
FAST BLINK – The management controller is in the process of 
communicating with the Chassis Management Module (CMM) during 
initial insertion of the expansion canister. If the expansion canister 
remains in this state for more than 10 minutes, try reseating it. If the 
state persists, follow the hardware replacement procedure for the 
expansion canister.
7
Note: Although it is useful to understand the meaning of the expansion canister LEDs, 
service actions should always start by examining the IBM Flex System V7000 
management GUI event log and running the Fix Procedures for the reported errors in 
the order suggested
LED 
layout
LED Name
Color
States
Expansion 
canister fault
Amber
��
OFF – The expansion canister is operating correctly, or it has not been 
possible to isolate the issue to make it the expansion canister.
��
ON SOLID – The expansion canister has failed and should be 
replaced. If it is available, use the IBM Flex System V7000 
management GUI event log fix procedures to guide the replacement.
Expansion 
canister 
identify
Blue
��
OFF – The expansion canister is not in identify state by the controller 
management system
��
ON SOLID – The expansion canister has been identified in response to 
the controller management system
��
BLINK – This occurs during power on and power-on self-test (POST) 
activitie
Expansion 
enclosure fault
Amber
��
This LED is not used and it is always off.