Chapter 2 — Replacing Parts 
 
 
Visor
Large scan
mount
bracket
Shield
SE1200
scan flex
engine
Screw
(2 places)
 
Insert the scan engine in the scan mount bracket and attach it with the 
two Phillips screws removed in Step 4. 
Insert the scan engine assembly into the bottom cover and attach with 
the four Phillips screws removed in Step 2. 
Close the CK30. For help, see “Closing the CK30” on page 27. 
Replacing the EV10 Scanner 
To replace the EV10 scanner, you need the following tools: 
•  T10 Torx screwdriver 
•  Small Phillips screwdriver 
You also need one or more of the following parts depending on what you 
need to replace: 
•  EV10 scan engine assembly (P/N 3-131010-01-02) 
•  EV10 engine insulator (P/N 073657-001) 
•  EV10 engine ground spring (P/N 073495-001) 
•  EV10 scan flex assembly (P/N 072782-002) 
•  Small scan mount bracket (P/N 072864-001) 
•  Phillips 4-20 x .250 thread-form screw (P/N 525023) 
•  Phillips M1.6 x 3mm steel screw (P/N 591883-001) 
To replace the EV10 scanner 
 
Open the CK30. For help, see “Opening the CK30” on page 9. 
From the bottom cover, remove the three Phillips screws that attach 
the EV10 scan engine assembly as shown in the next illustration. 
Lift the scan engine assembly away from the bottom cover. 
CK30 Handheld Computer Service Manual 